U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Inter-Laboratory Assessment of a Prototype Multiplex Kit for Determination of Recent HIV-1 Infection

Supporting Files
File Language:
English


Details

  • Alternative Title:
    PLoS One
  • Personal Author:
  • Description:
    Background

    Accurate and reliable laboratory-based assays are needed for estimating HIV-1 incidence from cross-sectional samples. We recently described the development of a customized, HIV-1-specific Bio-Plex assay that allows for the measurement of HIV-specific antibody levels and avidity to multiple analytes for improved HIV-1 incidence estimates.

    Methods

    To assess intra- and inter-laboratory assay performance, prototype multiplex kits were developed and evaluated by three distinct laboratories. Longitudinal seroconversion specimens were tested in parallel by each laboratory and kit performance was compared to that of an in-house assay. Additionally, the ability of the kit to distinguish recent from long-term HIV-1 infection, as compared to the in-house assay, was determined by comparing the reactivity of known recent (infected <6 months) and long-term (infected >12 months) drug naïve specimens.

    Results

    Although the range of reactivity for each analyte varied between the prototype kit and in-house assay, a measurable distinction in reactivity between recent and long-term specimens was observed with both assays in all three laboratories. Additionally, kit performance was consistent between all three laboratories. The intra-assay coefficient of variation (CV), between sample replicates for all laboratories, ranged from 0.5% to 6.1%. The inter-laboratory CVs ranged from 8.5% to 21.3% for gp160-avidity index (a) and gp120-normalized mean fluorescent intensity (MFI) value (n), respectively.

    Conclusion

    We demonstrate the feasibility of producing a multiplex kit for measuring HIV antibody levels and avidity, with the potential for improved incidence estimates based on multi-analyte algorithms. The availability of a commercial kit will facilitate the transfer of technology among diverse laboratories for widespread assay use.

  • Subjects:
  • Source:
    PLoS One. 2013; 8(10).
  • Document Type:
  • Funding:
  • Volume:
    8
  • Issue:
    10
  • Collection(s):
  • Main Document Checksum:
    urn:sha256:334a72ac07b688219451546c6ef44b34f5a7b9ae1ce2fe8285f986667bd5af25
  • Download URL:
  • File Type:
    Filetype[PDF - 673.47 KB ]
File Language:
English
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.