A High-Throughput, Turbulent-Mixing, Condensation Aerosol Concentrator for Direct Aerosol Collection as a Liquid Suspension (Dataset)

Dataset Public Domain


Details

  • Corporate Authors:
  • Description:
    Trace measurement of aerosol chemical composition in workplace atmospheres requires the development of high-throughput aerosol collectors that are compact, hand-portable, and can be operated using personal pumps. We describe the design and characterization of a compact, high flow, Turbulent-mixing Condensation Aerosol-in-Liquid Concentrator (TCALC) that allows direct collection of aerosols as liquid suspensions, for off-line chemical, biological, or microscopy analysis. The TCALC unit, measuring approximately 12 × 16 × 18 cm, operates at an aerosol sample flowrate of up to 10 L min-1, using rapid mixing of a hot flow saturated with water vapor and a cold aerosol sample flow, thereby promoting condensational growth of aerosol particles. We investigated the effect of operating parameters such as vapor temperature, growth tube wall temperature, and aerosol sample flowrate, along with the effect of particle diameter, inlet humidity, aerosol concentration, and operation time on TCALC performance. Nanoparticles with an initial aerodynamic diameter ≥ 25 nm could grow to droplet diameters > 1400 nm with an efficiency ≥ 80%. Good droplet growth efficiency was achieved for sampled aerosol relative humidity ≥ 9%. We measured complete aerosol collection for concentrations of ≤ 3×105 cm-3. The results showed good agreement between the particulate mass collected through the liquid collector and direct filter collection. The TCALC eliminates the need for sample preparation and filter digestion during chemical analysis, thereby increasing sample recovery and substantially improving the limit of detection and sensitivity of off-line trace analysis of collected liquid samples. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • DOI:
  • Publisher:
  • Document Type:
  • Genre:
  • Place as Subject:
  • CIO:
  • Division:
  • Topic:
  • Location:
  • NIOSHTIC Number:
    nn:20070347
  • Citation:
    Cincinnati, OH: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Research Dataset RD-1098-2024-0, 2024 Dec; :dataset
  • Contact Point Address:
    Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), Cincinnati, OH
  • Federal Fiscal Year:
    2025
  • NORA Priority Area:
  • Peer Reviewed:
    False
  • Source Full Name:
    A high-throughput, turbulent-mixing, condensation aerosol concentrator for direct aerosol collection as a liquid suspension
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:703566af635e0b0074bf00e94275d8e3438a849796d8f1229b581b1e1af87b099b190dee60e1bffcb346c2f2e5a07c826736760b2d38228e9a743fba45f4f631
  • Download URL:
  • File Type:
    Filetype[PDF - 236.50 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.