U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Inverse Kinematics in Cervical Spine Models: Effects of Scaling and Model Degrees of Freedom for Extension and Flexion Movements



Details

  • Personal Author:
  • Description:
    Intervertebral kinematics can affect model-predicted loads and strains in the spine; therefore knowledge of expected vertebral kinematics error is important for understanding the limitations of model predictions. This study addressed how different kinematic models of the neck affect the prediction of intervertebral kinematics from markers on the head and trunk. Eight subjects executed head and neck extension-flexion motion with simultaneous motion capture and biplanar dynamic stereo-radiography (DSX) of vertebrae C1-C7. A generic head and neck model in OpenSim was scaled by marker data, and three versions of the model were used with an inverse kinematics solver. The models differed according to the number of independent degrees of freedom (DOF) between the head and trunk: 3 rotational DOF with constraints defining intervertebral kinematics as a function of overall head-trunk motion; 24DOF with 3 independent rotational DOF at each level, skull-T1; 48DOF with 3 rotational and 3 translational DOF at each level. Marker tracking error was lower for scaled models compared to generic models and decreased as model DOF increased. The largest mean absolute error (MAE) was found in extension-flexion angle and anterior-posterior translation at C1-C2, and superior-inferior translation at C2-C3. Model scaling and complexity did not have a statistically significant effect on most error metrics when corrected for multiple comparisons, but ranges of motion were significantly different from DSX in some cases. This study evaluated model kinematics in comparison to gold standard radiographic data and provides important information about intervertebral kinematics error that are foundational to model validity. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    0021-9290
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Volume:
    175
  • NIOSHTIC Number:
    nn:20070130
  • Citation:
    J Biomech 2024 Oct; 175:112302
  • Contact Point Address:
    Anita N. Vasavada, Voiland School of Chemical Engineering and Bioengineering, Department of Integrative Physiology and Neuroscience, Washington State University, Pullman, WA 99164-1505, USA
  • Email:
    vasavada@wsu.edu
  • Federal Fiscal Year:
    2025
  • Performing Organization:
    Texas Engineering Experiment Station
  • Peer Reviewed:
    True
  • Start Date:
    20150901
  • Source Full Name:
    Journal of Biomechanics
  • End Date:
    20190831
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:367d36df0985f0a8636086bdfc63b4a1be69b75d9aaf7bd69c10b1736c18fe59b5b37baa5f83638253bc0c09611a2d4825080795a98ffb3c5ed1167f0dbee4b1
  • Download URL:
  • File Type:
    Filetype[PDF - 5.36 MB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.