U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

2-Dimensional Benchtop X-Ray Fluorescence Approaches to Exposure Assessment



Details

  • Personal Author:
  • Description:
    Introduction: Advances in benchtop micro-XRF allow for the potential expansion of 2D exposure assessment for epidemiological and toxicological samples down to a spatial resolution of 10um for simultaneous 30+ element quantification. We aimed to identify the advantages of this method in comparison to other more traditional methods. Methods: We used a comparison of methodologies between synchrotron XRF at the Advanced Photon Source at Argonne National Lab, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), and micro-XRF using a Bruker M4 Tornado system in order to measure sectioned human tibia bone samples, paraffin embedded rat lung, and sectioned human teeth samples to identify potential variations among the techniques by specimen type, limits of detection, and quantification. Results: We found strong agreements between the quantification results from each method (>90% agreement for samples). For a 1 second dwell time, we identified a detection limit of 4.8 ppm for a single 10um pixel. Using a longer dwell time or summation of pixels results in correspondingly lower detection limits. Quantification differences between approaches, particularly with LA-ICP-MS where data is normalized to a major element, did not have broad impacts on the data. Conclusion: The detection limit of the micro-XRF was within range to analyze teeth and bone effectively with short measurement times. For tissue based toxicological studies, the time per pixel will need to be increased to take advantage of the 10um resolution, but for many epidemiological tissues such as teeth, the benchtop XRF can accurately quantify exposures. Micro-XRF has significant advantages over LA-ICP-MS sample destruction or the necessity for beamtime at a synchrotron source. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • Publisher:
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Volume:
    2022
  • Issue:
    1
  • NIOSHTIC Number:
    nn:20069928
  • Citation:
    34th Annual Conference of the International Society for Environmental Epidemiology (ISEE), September 18-21, 2022, Athens, Greece. Herndon, VA: ISEE, 2022 Sep; 2022(1):P-0858
  • Federal Fiscal Year:
    2022
  • Performing Organization:
    Purdue University
  • Peer Reviewed:
    False
  • Start Date:
    20210901
  • Source Full Name:
    34th Annual Conference of the International Society for Environmental Epidemiology (ISEE), September 18-21, 2022, Athens, Greece
  • End Date:
    20220731
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:ba023c23fb7bca5f3f8d040b4a17cba708ebbb8701b419c3a66d35df38d163689c8f6745676ca1102ec44874e02c574f69afa2c778ab2642c2ae85d752f4f8d7
  • Download URL:
  • File Type:
    Filetype[PDF - 429.98 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.