Use of ozone generating devices to improve indoor air quality
Public Domain
-
1995/06/01
Details
-
Personal Author:
-
Description:A review of the safety of ozone (10028156) generating devices and their ability to improve air quality was presented. Reports on the health effects of ozone at various concentrations were cited as well as current exposure standards. These standards included the National Ambient Air Quality Standard (NAAQS) of 120 parts per billion (ppb) averaged over 1 hour (hr), the OSHA permissible exposure level (PEL) of 100ppb averaged over an 8hr day, and the Food and Drug Administration limit of 50ppb for ozone generating devices in enclosed, occupied spaces. The limits of olfactory detection of ozone and rapid olfactory fatigue were discussed. Reported halflives of common residential air contaminants in the presence of ozone were listed. In a discussion of ozone chemistry, it was pointed out that only unsaturated alkenes showed significant reactivity with ozone. The products of such reactions were aldehydes, ketones, and organic acids, which may be more toxic than the precursor alkene. Experimental evidence demonstrated the occurrence of such reactions when ozone generating devices were used in the presence of alkenes. Other cited reports suggested a potential for excessive exposure and questioned their effectiveness in removing air pollutants. The author concludes that while the levels of ozone produced are higher than permissible levels, they are still too low to remove contaminants from air. Dilution ventilation is suggested as a safer and more efficient way to improve indoor air quality. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0002-8894
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Volume:56
-
Issue:6
-
NIOSHTIC Number:nn:00226883
-
Citation:Am Ind Hyg Assoc J 1995 Jun; 56(6):590-598
-
Contact Point Address:Mark F. Boeniger, Industrywide Studies Branch, Division of Surveillance, Hazard Evaluations, and Field Studies, National Institute for Occupational Safety and Health, 4676 Columbia Parkway, Cincinnati, OH 45226-1998
-
CAS Registry Number:
-
Federal Fiscal Year:1995
-
Peer Reviewed:True
-
Source Full Name:American Industrial Hygiene Association Journal
-
Collection(s):
-
Main Document Checksum:urn:sha-512:e6fcba2d1ca4b153d0aa75a63f119816c84db65ecbdcb719cd7eb8ab390ed7cd174e281113238292213110df1e1eaea1912d3d5d788d05d134707272557e7b90
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like