Respirable aerosol sampler performance testing
Public Domain
-
1994/11/01
-
Details
-
Personal Author:
-
Description:The performance of two respirable aerosol samplers was tested to determine performance specifications. Factors taken into consideration included sampling efficiency, bias, sampling method imprecision, intersampler variability, pump flowrate inaccuracy, filter weighing error, and accuracy. The two respirable aerosol samplers chosen for evaluation were the Higgins and Dewell (HD) sampler and the 10 millimeter nylon Dorr Oliver cyclone. Four tests were repeated at four different flowrates on each of eight samplers. Aerosol, upstream to the sampler, was introduced in a low speed wind tunnel. Procedures were used to ensure homogeneity of the aerosol in the areas being tested by the samplers. The test aerosol selected was potassium-sodium-tartrate (304596). Mass median diameter of the particles was 4 micrometers, with a standard deviation of 2.2. Upper limits on sampler inaccuracy were determined. The authors recommend that the HD sampler be operated at 2.2 liters per minute and that the nylon cyclone be operated at 1.7 liters per minute. These recommendations closely match the international sampler standard adopted by international organizations. The authors suggest that adoption of performance standards could result in improvements in sampler design, including the introduction of samplers with added capabilities. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0002-8894
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Volume:55
-
Issue:11
-
NIOSHTIC Number:nn:00223799
-
Citation:Am Ind Hyg Assoc J 1994 Nov; 55(11):1036-1046
-
CAS Registry Number:
-
Federal Fiscal Year:1995
-
Peer Reviewed:True
-
Source Full Name:American Industrial Hygiene Association Journal
-
Collection(s):
-
Main Document Checksum:urn:sha-512:d9f787053ac713575c7d279c580d97b5576ae532768ea1b7beb1c9a8d56fb38516502b7384ead3cedf5f766b412e77883f7f9e47f41588d7594af3203d5abd08
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like