U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

"Worst Case" aerosol testing parameters: II. Efficiency dependence of commercial respirator filters on humidity pretreatment

Public Domain


Details

  • Personal Author:
  • Description:
    Filter preconditioning recommendations offered by the American National Standards Institute (ANSI) were tested in this study. These recommendations called for the unprotected respirator filter media to be preconditioned in a 38 degree-C and 85 percent relative humidity (RH) environment for 24 hours prior to any testing of the efficiency of the media. The current study examined the efficiencies of filter materials following exposures of 1, 7, 14, 28 and 42 days to these preconditioning treatments. Tests were conducted using six resin impregnated wool felt filters using a 0.6 micrometer mass median aerodynamic diameter (MMAD) unneutralized sodium-chloride (NaCl) particle at a flow rate of 32 liters/minute. Additional studies of the same material used flow rates of 32 and 77 liters/minute. Other tests involved four different types of electrostatic filters using a monodispersed 0.3 micrometer diameter dioctyl-phthalate (DOP) aerosol and an NaCl aerosol with a 1.0 micrometer MMAD. Filter face velocities of 5.4 and 6.5 centimeters/second (cm/s) were used. Depending on the preconditioning time (1 to 42 days) a 2 to 6 percent drop in the efficiency of the electrostatic filters was demonstrated. High efficiency filters retained their level of operation, 99.97 percent effective, in spite of preconditioning. The particle size appears to be important in determining efficiency and perhaps has some interrelationship to humidity levels. The authors conclude that some degradation does occur in the efficiency of filter material following unprotected preconditioning when tested with a neutralized worst case aerosol. As it is not unreasonable to expect that filter material may well be stored under conditions such as these for some time, the fact that the efficiency deteriorates with time becomes important. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    0002-8894
  • Document Type:
  • Genre:
  • Place as Subject:
  • CIO:
  • Division:
  • Topic:
  • Location:
  • Pages in Document:
    265-270
  • Volume:
    50
  • Issue:
    5
  • NIOSHTIC Number:
    nn:00187674
  • Citation:
    Am Ind Hyg Assoc J 1989 May; 50(5):265-270
  • Federal Fiscal Year:
    1989
  • Peer Reviewed:
    True
  • Source Full Name:
    American Industrial Hygiene Association Journal
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:fb6dea66afed53f6b2f64db01f2a5f05ac34ff2e332609729e9b69e7b1b5cf8a6d933f3e7e1db4f88dec281de55be4b4e473b76625d37758f6b7e29eeb80f61c
  • Download URL:
  • File Type:
    Filetype[PDF - 397.69 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.