Precautionary practices for administering anesthetic gases: a survey of physician anesthesiologists, nurse anesthetists and anesthesiologist assistants
Public Domain
-
2016/10/01
Details
-
Personal Author:
-
Description:Scavenging systems and administrative andwork practice controls for minimizing occupational exposure to waste anesthetic gases have been recommended for many years. Anesthetic gases and vapors that are released or leak out during medical procedures are considered waste anesthetic gases. To better understand the extent recommended practices are used, the NIOSH Health and Safety Practices Survey of Healthcare Workers was conducted in 2011 among members of professional practice organizations representing anesthesia care providers including physician anesthesiologists, nurse anesthetists, and anesthesiologist assistants. This national survey is the first to examine self-reported use of controls to minimize exposure to waste anesthetic gases among anesthesia care providers. The survey was completed by 1,783 nurse anesthetists, 1,104 physician anesthesiologists, and 100 anesthesiologist assistants who administered inhaled anesthetics in the seven days prior to the survey.Working in hospitals and outpatient surgical centers, respondents most often administered sevoflurane and, to a lesser extent desflurane and isoflurane, in combination with nitrous oxide. Use of scavenging systems was nearly universal, reported by 97% of respondents. However, adherence to other recommended practices was lacking to varying degrees and differed among those administering anesthetics to pediatric (P) or adult (A) patients. Examples of practices which increase exposure risk, expressed as percent of respondents, included: using high (fresh gas) flow anesthesia only (17% P, 6% A), starting anesthetic gas flow before delivery mask or airway mask was applied to patient (35% P; 14% A); not routinely checking anesthesia equipment for leaks (4% P, 5% A), and using a funnel-fill system to fill vaporizers (16%). Respondents also reported that facilities lacked safe handling procedures (19%) and hazard awareness training (18%). Adherence to precautionary work practices was generally highest among nurse anesthetists compared to the other anesthesia care providers. Successful management of waste anesthetic gases should include scavenging systems, hazard awareness training, availability of standard procedures to minimize exposure, regular inspection of anesthesia delivery equipment for leaks, prompt attention to spills and leaks, and medical surveillance. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:1545-9624
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Volume:13
-
Issue:10
-
NIOSHTIC Number:nn:20048527
-
Citation:J Occup Environ Hyg 2016 Oct; 13(10):782-793
-
Contact Point Address:James M. Boiano, National Institute for Occupational Safety and Health, Division of Surveillance, Hazard Evaluations and Field Studies, 1090 Tusculum Ave., MS R-17, Cincinnati, OH 45226-1998
-
Email:jboiano@cdc.gov
-
CAS Registry Number:
-
Federal Fiscal Year:2017
-
NORA Priority Area:
-
Peer Reviewed:True
-
Source Full Name:Journal of Occupational and Environmental Hygiene
-
Collection(s):
-
Main Document Checksum:urn:sha-512:9525981af3e27ad657eeb4d9f5b6784e2fa350676bee60edbd7b41f1912ca206f2dbfa570e2ab974924c85c7ddf359f648dae5ff9e9265bf2929d37255aa8389
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like