Particle size distribution in aluminum manufacturing facilities

Peer Reviewed


Details

  • Personal Author:
  • Description:
    As part of exposure assessment for an ongoing epidemiologic study of heart disease and fine particle exposures in aluminum industry, area particle samples were collected in production facilities to assess instrument reliability and particle size distribution at different process areas. Personal modular impactors (PMI) and Minimicro-orifice uniform deposition impactors (MiniMOUDI) were used. The coefficient of variation (CV) of co-located samples was used to evaluate the reproducibility of the samplers. PM(2.5) measured by PMI was compared to PM(2.5) calculated from MiniMOUDI data. Mass median aerodynamic diameter (MMAD) and concentrations of sub-micrometer PM(1.0) and quasi-ultrafine PM(0.56) particles were evaluated to characterize particle size distribution. Most of CVs were less than 30%. The slope of the linear regression of PMI_PM(2.5) versus MiniMOUDI_PM(2.5) was 1.03 mg/m3 per mg/m3 ( +/- 0.05), with correlation coefficient of 0.97 (+/- 0.01). Particle size distribution varied substantively in smelters, whereas it was less variable in fabrication units with significantly smaller MMADs (arithmetic mean of MMADs: 2.59 micom in smelters vs. 1.31 micom in fabrication units, p = 0.001). Although the total particle concentration was more than two times higher in the smelters than in the fabrication units, the fraction of PM(10) which was PM(1.0) or PM(0.56) was significantly lower in the smelters than in the fabrication units (p < 0.001). Consequently, the concentrations of sub-micrometer and quasi-ultrafine particles were similar in these two types of facilities. It would appear, studies evaluating ultrafine particle exposure in aluminum industry should focus on not only the smelters, but also the fabrication facilities. Description provided by NIOSH
  • Subjects:
  • Keywords:
  • ISSN:
    1927-0909
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Pages in Document:
    79-88
  • Volume:
    3
  • Issue:
    4
  • NIOSHTIC Number:
    nn:20046914
  • Citation:
    Environ Pollut 2014 Oct; 3(4):79-88
  • Contact Point Address:
    Sa Liu, Division of Environmental Health Sciences, School of Public Health, University of California, Berkeley, 50 University Hall, #7360, Berkeley, CA 94720-7360, USA
  • Email:
    saliu@berkeley.edu
  • Federal Fiscal Year:
    2015
  • NORA Priority Area:
  • Performing Organization:
    Stanford University
  • Peer Reviewed:
    True
  • Start Date:
    20110901
  • Source Full Name:
    Environment and Pollution
  • End Date:
    20200831
  • Download URL:
  • File Type:
    Filetype[PDF - 266.59 KB]
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:da3f62deaeeaf2c553fa57c0bdf9d056a2626237a693dc00222c6d498c74e4144470d3beb324a046bffe01ec4752690d0fcbdd5584774cc90a33a46164cff283
ON THIS PAGE
 Was this page helpful?
 Found an issue?
Send us an email at:
CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.