Validation of tri-axial accelerometer for the calculation of elevation angles
-
2015/05/08
-
Details
-
Personal Author:
-
Description:One of the main challenges in occupational studies of musculoskeletal disorders (MSDs) is how to quantify workers' exposures to risk factors during a workday. Studies have indicated that workers who spend much of the day with arms elevated higher than 60 degrees are at increased risk of shoulder injury. Researchers in occupational studies commonly use accelerometers to measure arm elevation angles, but these devices are sensitive to linear acceleration and can only assess two axes of rotation. In the present study researchers tested the Virtual Corset, a pager-sized, battery powered, tri-axial linear accelerometer originally designed to measure trunk flexion. The Virtual Corset accurately predicted arm elevation angles under static conditions, but using the device effectively for angle measurement under dynamic conditions proved difficult. For the static condition, the RMS error of the calculated elevation angles was found to be less than 1 degree. Under dynamic conditions the calculated elevation angle error ranged from 10 degrees to 80 degrees. The farther the Virtual Corset was located on the arm from the axis of rotation (the shoulder), the higher the errors. From a practical point of view, use of the Virtual corset for quantifying shoulder elevation for static or sustained postures is appropriate, but if used for dynamic work, the elevation angle RMS errors of 10 degrees and above might be too big and meaningless to analyze. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Publisher:
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:1
-
NIOSHTIC Number:nn:20046799
-
Citation:Silver Spring, MD: CPWR-The Center for Construction Research and Training, 2015 May; :1
-
Email:lwelch@cpwr.com
-
Federal Fiscal Year:2015
-
Performing Organization:CPWR - The Center for Construction Research and Training, Silver Spring, Maryland
-
Peer Reviewed:False
-
Start Date:20090901
-
Source Full Name:Validation of tri-axial accelerometer for the calculation of elevation angles
-
End Date:20240831
-
Collection(s):
-
Main Document Checksum:urn:sha-512:fb402c83a52b4beccefa22f54242fc2b45e55a1ce090cb5234dae5e922de7c8959623beab9119902f009855a9a19264c65003b717f867735164d560df2b05fde
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like