U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Performance of exposure models in experimental rom for various thermal conditions, airflow and worker locations



Details

  • Personal Author:
  • Description:
    Most simple mathematical models now in use for estimating exposure do not account for variation in airflow patterns and thermal conditions. Here measured breathing zone concentrations were compared with model estimates for various physical factors to explore model applicability. Contaminant distribution in the breathing zone (elevation=1.5m) in a 2.86(L)x2.35m(H)x 2.86m(W) room with a contaminant source (99.5% propylene) on a 1-m high pedestal was monitored using photoionization detector for steady conditions. Factorial combinations of two Reynolds number (Re=2870 and 2070), two Archimedes number (Ar=14700 and 3(000) and three worker locations (absent, north of source, east of source) were studied. A mannequin located at 0.5m from the source was used to represent a worker. Concentration estimated from the completely-mixed models for one-zone (CM- 1) and two-zones (CM-2), and the uniform turbulent diffusivity model (UD) were compared with experimental results. Model performance was evaluated in the "near-field" and "farfield" of the source. In the near field for the CM-l, CM-2, and UD models, the mean errors (+/- SD) were- 44(+/-17)%, 28(+/-39)% and 74(+/-106)%. The farfield mean errors for the CM-l and CM-2 were both -17(+/-14.9)% because these models are mathematically identical for the far field. The far-field mean error for the UD model was -20(+/-21)%. Although the mean error in the near field for CM-2 was lower than that for CM-l, the CM-2 estimates showed more variability than the CM-I estimates. In the near field, CM-2 was least biased. Also it was the best model for exposure asssment for protection of workers' health because CM-l tended to underestimate the near-field concentration. UD demonstrated the worst performance in the near field. All three models performed better in the far field. Wlth similar error means and standard deviations. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • Publisher:
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Pages in Document:
    53-54
  • NIOSHTIC Number:
    nn:20045437
  • Citation:
    American Industrial Hygiene Conference and Exposition, June 1-6, 2002, San Diego, California. Fairfax, VA: American Industrial Hygiene Association, 2002 Jun; :53-54
  • Federal Fiscal Year:
    2002
  • Performing Organization:
    University of South Carolina at Columbia, Columbia, South Carolina
  • Peer Reviewed:
    False
  • Start Date:
    20010901
  • Source Full Name:
    American Industrial Hygiene Conference and Exposition, June 1-6, 2002, San Diego, California
  • End Date:
    20050831
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:8babc5f2eb2388c6b9c2a7280a45ccfa07923e1a78861a14716e78d46cfc76c7e554aad3f2656d7d0b9c0d9f2560c3383b381171c3908cb8b69ca7419da5d80f
  • Download URL:
  • File Type:
    Filetype[PDF - 318.36 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.