U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Development of a transportable neutron activation analysis system to quantify manganese in bone in vivo: feasibility and methodology



Details

  • Personal Author:
  • Description:
    This study was conducted to investigate the methodology and feasibility of developing a transportable neutron activation analysis (NAA) system to quantify manganese (Mn) in bone using a portable deuterium-deuterium (DD) neutron generator as the neutron source. Since a DD neutron generator was not available in our laboratory, a deuterium-tritium (DT) neutron generator was used to obtain experimental data and validate the results from Monte Carlo (MC) simulations. After validation, MC simulations using a DD generator as the neutron source were then conducted. Different types of moderators and reflectors were simulated, and the optimal thicknesses for the moderator and reflector were determined. To estimate the detection limit (DL) of the system, and to observe the interference of the magnesium (Mg) y line at 844 keV to the Mn y line at 847 keV, three hand phantoms with Mn concentrations of 30 parts per million (ppm), 150 ppm, and 500 ppm were made and irradiated by the DT generator system. The Mn signals in these phantoms were then measured using a 50% high-efficiency high-purity germanium (HPGe) detector. The DL was calculated to be about 4.4 ppm for the chosen irradiation, decay, and measurement time. This was calculated to be equivalent to a DL of about 3.3 ppm for the DD generator system. To achieve this DL with one 50% high-efficiency HPGe detector, the dose to the hand was simulated to be about 37 mSv, with the total body equivalent dose being about 23µSv. In conclusion, it is feasible to develop a transportable NAA system to quantify Mn in bone in vivo with an acceptable radiation exposure to the subject. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    0967-3334
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Volume:
    34
  • Issue:
    12
  • NIOSHTIC Number:
    nn:20044909
  • Citation:
    Physiol Meas 2013 Dec; 34(12):1593-1609
  • Contact Point Address:
    Linda H Nie, School of Health Sciences, Purdue University, West Lafayette, IN 47907
  • Email:
    hnie@purdue.edu
  • CAS Registry Number:
  • Federal Fiscal Year:
    2014
  • Performing Organization:
    Purdue University, West Lafayette, Indiana
  • Peer Reviewed:
    True
  • Start Date:
    20120701
  • Source Full Name:
    Physiological Measurement
  • End Date:
    20150630
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:a2a40ad46dce939e4b9fb015c1818663d2b48dea0542df0c44d9deb6376a210dc7054aa1e0072961e5229fd6188faae1763bf9ff7894fad45a781a0004a5c7e1
  • Download URL:
  • File Type:
    Filetype[PDF - 785.23 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.