A proposed simple model for estimating occupational radiation dose to staff from veterinary (18)F-FDG pet procedures
-
2014/05/01
-
Details
-
Personal Author:
-
Description:Several studies have been conducted concerning the radiation dose to hospital personnel from positron emission tomography (PET) radiopharmaceuticals, but to date only one parallel study has been conducted for veterinary staff. Veterinary patients present challenges not encountered with human patients, as they require anesthesia and therefore more intensive monitoring than human patients. This paper presents a simple model for estimating the effective radiation dose to veterinary staff using occupational dose data from PET studies at Colorado State University's (CSU) James L. Voss Veterinary Teaching Hospital. The model consists of three point sources within a soft tissue cylinder, and sample calculations are provided for estimating dose to nuclear medicine technologists and an anesthesia technologist based on four different sized dogs. The estimated doses are within the range of actual occupational doses published previously. There are different protocols for the sequence of events in veterinary PET, specifically the order of anesthesia induction and radiopharmaceutical injection. When F-FDG injection is performed prior to anesthesia induction, the estimated dose is between 1.5 and 3.6 times higher than the doses received if injection is done after anesthesia induction, although expected doses for both protocols are below occupational dose limits based on a case load of 100 veterinary patients per year. The model is based on the techniques used at CSU, but it can be modified for different hospitals as well as differently sized animals. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0017-9078
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Volume:106
-
Issue:5
-
NIOSHTIC Number:nn:20044359
-
Citation:Health Phys 2014 May; 106(5):583-591
-
Contact Point Address:Nicole E. Martinez; 1681 Campus Delivery, Fort Collins, CO 80523
-
Email:n.martinez@colostate.edu
-
Federal Fiscal Year:2014
-
Performing Organization:University of Colorado, Denver
-
Peer Reviewed:True
-
Start Date:20070701
-
Source Full Name:Health Physics
-
End Date:20250630
-
Collection(s):
-
Main Document Checksum:urn:sha-512:2262333f952d2ba628a7618b00a8f31c4259964821e09f008bf7102086a1da109bf3521193cd30a552a4e7655fa66e2580e6586ac61f74408ea47751fda7fac0
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like