Comparison of lead and tin concentrations in air at a solder manufacturer from the closed-face 37-mm cassette with and without a custom cellulose-acetate cassette insert
Public Domain
-
2014/12/01
-
Details
-
Personal Author:
-
Description:A polyvinyl chloride (PVC) cassette insert with PVC filter (ACCU-CAP) in a 37-mm closed -face cassette (CFC) was designed for gravimetric analysis. A customized version of the ACCU-CAP, also to be used in the CFC, was manufactured from an acid-digestible cellulose-acetate cassette insert joined to a mixed cellulose ester (MCE) filter for wet chemical analysis. The aim of this study was to compare metal particle concentrations as sampled by the customized insert (CI) in a CFC sampler with the traditional sampling method using only a MCE filter in the CFC. Thirty-nine personal and 13 area samples were taken using paired filter-based CFC and the CI in CFC samplers at a solder manufacturing plant. The CI was removed from its CFC, digested and analyzed as a whole. The MCE filter from the typical CFC was removed for analysis and then the interior of the cassette was wiped with Ghost Wipe for a separate analysis. The MCE filter only, Ghost Wipe, and CI were separately dissolved in heated nitric acid for ICP-MS analysis. Overall, the geometric mean concentration of the filter-only (FO) samples was considerably lower than that of the CI samples, by 53% for lead and 32% for tin. However, if the FO analysis was added to the corresponding Ghost Wipe analysis, i.e., filter+interior wipe (FW), the geometric mean concentrations of the FW results were similar to those of the CI results (by 113% for lead and 98% for tin). For both lead and tin the comparison of (log-transformed) metal concentrations between the FW and CI results showed no statistically significant difference (p-value=0.3009 for lead and 0.800 for tin), while the comparison between the FO and CI results shows statistically significant differences (all p-values<0.05). In conclusion, incorporating the sampler internal non-filter deposits by wiping or use of an internal filter capsule gave higher results than analyzing only the filter. Close agreement between the two methods of including non-filter deposits is an indication of general equivalency. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:1545-9624
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Volume:11
-
Issue:12
-
NIOSHTIC Number:nn:20044357
-
Citation:J Occup Environ Hyg 2014 Dec; 11(12):819-825
-
Contact Point Address:Eun Gyung Lee, National Institute for Occupational Safety and Health (NIOSH), Health Effects Laboratory Division, Exposure Assessment Branch, 1095 Willowdale Road, Morgantown, WV 26505
-
Email:dtq5@cdc.gov
-
CAS Registry Number:
-
Federal Fiscal Year:2015
-
NORA Priority Area:
-
Peer Reviewed:True
-
Source Full Name:Journal of Occupational and Environmental Hygiene
-
Collection(s):
-
Main Document Checksum:urn:sha-512:72077f5fe57aef89e90edcadf558ee10221dd3fd7faf95751ef8c898fc73617d54a49598f23b75e52699f72411ee49588311c25230821dbc4bbf422223fd506f
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like