Overwork contributes to serious burn injury
-
2006/05/01
Details
-
Corporate Authors:
-
Description:A journeyman electrician with over twenty years of experience was assigned to work on an electrical circuit in an electrical vault that contained voltages exceeding 4000 volts. He was fatigued from excessive overtime. Including the day of the accident, he had worked over eighty hours in the previous 5 days. He had intended to de-energize the circuit before beginning work. Unfortunately, he de-energized the wrong circuit. He went to the energized circuit to begin work and an electrical arc-flash/blast occurred. As the work was intended to be done de-energized, he was not wearing personal protective equipment, such as a face shield or insulating gloves. He was thrown backwards but did not fall or lose consciousness. He suffered burns to his face, neck and hand. Burn treatment required hospitalization for about a week. Injuries such as these may be prevented by taking the following steps: 1. Accurately identify the equipment to be worked on and the energy isolating devices that will de-energize it. 2. Establish an "electrically safe work condition" whenever possible. De-energize it, lock it out, ground it and test it. 3. Always test for the absence of voltage at the location of the work. When working with voltages exceeding 600 volts, attach a hot stick to a high voltage detector. This will keep the electrician a safe distance from a possible arc flash/blast. 4. Attach grounding cables/straps with the appropriate voltage and current ratings with a hot stick. 5. Schedule jobs to avoid excess overtime by employees. 6. Proper personal protective equipment should always be used. 7. Never wear rings, watches or other jewelry when working with electricity. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Publisher:
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:1
-
NIOSHTIC Number:nn:20044344
-
Citation:Olympia, WA: Washington State Department of Labor and Industries, 85-4-2006, 2006 May; :1
-
Contact Point Address:Safety and Health Assessment and Research for Prevention (SHARP) Program, Washington State Department of Labor and Industries, PO Box 44330, Olympia, WA 98504-4330
-
Federal Fiscal Year:2006
-
Performing Organization:Washington State Department of Labor and Industries
-
Peer Reviewed:False
-
Start Date:20050701
-
Source Full Name:Overwork contributes to serious burn injury
-
End Date:20260630
-
Collection(s):
-
Main Document Checksum:urn:sha-512:7e968c51ecc402d0a2d082b1716abcaa6bb20a57a0fe1d3e7b77afc8159988f07c9aff1d77383aaa97f31a50d3f356b5bc2279a780f771dbff7290e4f5a58aea
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like