U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Evaluation of mechanical properties of rat tibialis anterior tendon using two different approaches

Public Domain


Details

  • Personal Author:
  • Description:
    Tendon injuries may result in variations of its mechanical properties. Published data on the tendon stiffness of small animals, such as mouse and rat, are exclusively obtained by measuring grip-to-grip (g-t-g) displacement. Local strain concentration and relative sliding of the specimens in the clamps might affect the measured tendon deformation significantly. PURPOSE: To measure the mechanical properties of rat tibialis anterior tendon based on the real tendon deformation and to evaluate the error introduced by using the g-t-g displacement. METHODS: Five male Sprague Dawley rats (approximately 418g) were used in the study. After being sacrificed, the tibialis anterior tendons of each animal were isolated. Two reference marks were made on the tendons using permanent ink. A microscope video system was customized to observe and record the tendon deformation. Pattern recognition software was developed to obtain the displacement-time histories of the reference marks. The distances between the grips and the reference marks were approximately 7 and 5 mm, respectively. Cross-sectional areas of the specimens were measured under a constant compressional stress (0.1 MPa) using a custom-made slot gauge. The tendons were clamped between two custom-made metal grips and stretched to failure at a constant speed (1 mm/s) on a testing machine. Throughout the tests, the tendon specimens were submerged in PBS bath at 22 degrees C. The deformation of the specimens was quantified using the g-t-g method and displacements between the reference marks. RESULTS: The yield stress of the rat tibialis anterior tendon was approximately 140 MPa, which is consistent with the literature. The yield strain evaluated using the displacement between the reference marks was 5.5%, significantly smaller than that using the g-t-g method (10.5%). CONCLUSION: Measurement of tendon stiffness using the g-t-g method may underestimate the true tendon stiffness by approximately 50%. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    0195-9131
  • Document Type:
  • Genre:
  • Place as Subject:
  • CIO:
  • Division:
  • Topic:
  • Location:
  • Volume:
    35
  • Issue:
    5
  • NIOSHTIC Number:
    nn:20044067
  • Citation:
    Med Sci Sports Exerc 2003 May; 35(5)(Suppl 1):S360
  • Federal Fiscal Year:
    2003
  • Peer Reviewed:
    False
  • Source Full Name:
    Medicine and Science in Sports and Exercise
  • Supplement:
    1
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:41647d8071f298487c1eea7dec4e330ee77cfe61f7a1db1d47b4e4ea5d712ae44e22d1e70b144ef94f904d834fb895bf1ba726d39ba6bcb2c2d2708d7ba918e1
  • Download URL:
  • File Type:
    Filetype[PDF - 37.94 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.