Test Performance of Electronic Recording Peak Flow Meters
Public Domain
-
2002/04/01
-
Details
-
Personal Author:
-
Description:Electronic recording peak flow meters (EPFM) are increasingly being used for ambulatory monitoring of asthma The EPFM's decrease errors associated with manual entry of time and peak expiratory flow rate (PEFR) data into diaries. However, only limited data documents the performance of these devices in measuring PEFR. Four types of EPFM were evaluated. A computer-controlled piston was used to deliver the 26 flow-time waveforms recommended by the ATS for assessing performance in PEFR measurement. An algorithm accounting for EPFM resistance and gas compression was used to assure accurate delivery of waveforms. For 2 types of EPFM we assessed 10 devices and for the other 2 types we assessed 3 devices. Accuracy, intradevice precision, and interdevice precision were calculated as recommended by the A TS. Correlation between delivered and measured PEFR and coefficient of variation (CV) in measurement at each waveform was also assessed for each type of EPFM. All 4 types of meters met ATS standards for accuracy. Within the limits of numbers of devices studied, all meters met standards for intradevice precision and 2 of the 4 meters met standards for interdevice precision. Delivered and measured PEFR for a114 meters were strongly correlated, with r values ranging between 0.987 and 0.999. CV's over the range of PEFR studied for the various EPFM ranged between 0.2% and 9.5%. The EPFM studied performed well from the standpoint of accuracy in measuring PEFR They were more variable in their precision. However, the tested EPFM have performance characteristics that appear sufficient for ambulatory monitoring PEFR. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:1073-449X
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Volume:165
-
Issue:8
-
NIOSHTIC Number:nn:20022977
-
Citation:Am J Respir Crit Care Med 2002 Apr; 165(8)(Suppl):A497
-
Federal Fiscal Year:2002
-
NORA Priority Area:
-
Peer Reviewed:False
-
Source Full Name:American Journal of Respiratory and Critical Care Medicine, 2002 International Conference, The American Thoracic Society, Atlanta Georgia, May 17-22, 2002
-
Supplement:Suppl
-
Collection(s):
-
Main Document Checksum:urn:sha-512:9c083558900ba5aa36f84663684f8ca20977f607923bbc26b6aba5e61257782e91591f25ecbce136d0f82637413e4c470bc1f45f6e9190050a49d371f20fcfd1
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like