Thoracic Size-Selection of Fibres: Dependence of Penetration on Fibre Length for Five Thoracic Sampler Types
Public Domain
-
2002/08/01
-
By Maynard AD
Details
-
Personal Author:
-
Description:It has been suggested that the non-size-selective sampling methods currently used for fibrous aerosols potentially lead to the presence of large compact particles, agglomerates and fibre clumps in samples, which in turn reduce the accuracy and precision of the manual fibre counting techniques employed to analyse samples. The use of thoracic size-selective samplers has been proposed as an alternative, leading to the prevention of large particles reaching the collection substrate while at the same time bringing fibre sampling into line with general occupational aerosol sampling methodologies. Thoracic samplers should give good agreement with current sampling methods under ideal conditions based on aerodynamic fibre properties. However, the effect of fibre length on sampling efficiency is not known. The sampling efficiency of five thoracic samplers was therefore measured as a function of fibre length for respirable fibres between 10 and 60 microm long. These included the commercially available GK2.69 cyclone and the CATHIA sampler, the IOM thoracic sampler, a modified version of the SIMPEDS cyclone and a modified version of the IOM inhalable sampler. Length-monodisperse fibres were generated using a dielectrophoretic fibre classifier and sampler penetration was measured as a function of fibre length. No length-dependent sampling effects were observed for the CATHIA, GK2.69, modified SIMPEDS and modified IOM inhalable samplers for fibres <60 microm. Data for the IOM thoracic sampler showed a significant trend of reducing sampling efficiency for fibres >30 microm. Overall, the laboratory results indicated that the five sampler types are likely to perform as well as or better than the currently used 25 mm cowled sampler in the field. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0003-4878
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Volume:46
-
Issue:6
-
NIOSHTIC Number:nn:20022243
-
Citation:Ann Occup Hyg 2002 Aug; 46(6):511-522
-
Contact Point Address:Andrew D. Maynard, National Institute of Occupational Safety and Health, Division of Applied Research and Technology, 4676 Columbia Parkway, Cincinnati, OH, 45226
-
Email:amaynard@cdc.gov
-
Federal Fiscal Year:2002
-
NORA Priority Area:
-
Peer Reviewed:True
-
Source Full Name:Annals of Occupational Hygiene
-
Collection(s):
-
Main Document Checksum:urn:sha-512:8dafbcf081eb20bf2c40cc1b4032bb423e95cfd082acec6543a461fdb9a1792a9f6c2e358ecb0026db6da639d10bf6181ddd1621b8f8fe1b011de50e331c5adf
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like