    Wind tunnel experiments have been performed on a passive aerosol sampler. The sampler estimates average concentrations and size distributions using a deposition velocity model and the measured particle flux to the sampler. The small-scale wind tunnel incorporated a high-output aerosol generator that produced nonvolatile, polydisperse particles. An eight-stage impactor was connected to the tunnel with an isoaxial, isokinetic probe and was equipped with polycarbonate-membrane substrates saturated with oleic acid to minimize particle bounce. Before performing experiments, the tunnel's test section was characterized. Aerosol concentrations were determined to have a CV < 6%. The friction velocity, an index of turbulence, was found to range from 0.09 to 0.25 m/s for wind speeds of 1.5 to 5 m/s. The empirical portion of the deposition velocity model, gamma-m, was determined as a function of particle size by minimizing the sum-of-squares difference between impactor and passive sampler across all size bins and all experiments. The relatively simple correlation is a function of the particle Reynolds number only. Precision was assessed by running three passive samplers simultaneously in each experiment. The tests yielded CVPM2:5 = 18:1% and CVPM10 = 32:2%. ANOVA tests were conducted on accuracy and precision to see whether they depended on wind speed, relative humidity, or aerosol concentration, and accuracy was tested with respect to particle size. No significant trends were observed. Sensitivity analysis showed that the volume shape factor is the most important of the mass and shape conversion factors. If SEM is used, the passive sampler will exhibit some error when sampling volatile aerosols. Because concentrations fluctuate over time, long-term exposures measured by the passive sampler should be more accurate than conventional averages based on short-term samples. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    0278-6826
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Pages in Document:
    193-201
  • Volume:
    34
  • Issue:
    2
  • NIOSHTIC Number:
    nn:20021915
  • Citation:
    Aerosol Sci Technol 2001 Feb; 34(2):193-201
  • Contact Point Address:
    Jeff Wagner, Department of Environmental Sciences and Engineering, CB#7400, Rosenau Hall, Chapel Hill, NC 27599
  • Email:
    jrwagner@lbl.gov
  • Federal Fiscal Year:
    2001
  • NORA Priority Area:
  • Performing Organization:
    University of North Carolina
  • Peer Reviewed:
    True
  • Start Date:
    19980930
  • Source Full Name:
    Aerosol Science and Technology
  • End Date:
    20000929
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:39e7baf33fbc487a8d0816badecfe1276a6c9882bd886931347044631113ef54b75a4578bd179ed517b7f9fd5dc6bc6fff2c5468cf8e3d469915243818ca3907
  • Download URL:
  • File Type:
    Filetype[PDF - 566.94 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.