Mist Generation at a Machining Center
Public Domain
-
2000/01/01
Details
-
Personal Author:
-
Description:Control of occupational exposure to metalworking fluid mist generally involves enclosing the machining center and exhausting to an air cleaner that returns cleaned air to the workplace. To select an appropriate air cleaner, particle size and generation rate of the mists need to be known. Mist particle size and concentration were measured as a function of tool speed, fluid flow rate, and cutting rate at an enclosed machining center. A vertical machining center was totally enclosed and the air from this enclosure was exhausted into a duct where mist concentration and size distribution were measured using a time-of-flight aerosol spectrometer and a cascade impactor. Mist generation during the face milling of a 30231-cm piece of aluminum with a 10-cm diameter face mill was studied. Machining parameters were varied as a 22223 factorial experiment with these variables: coolant flow rate (18 and 44 m/sec), tool rpm (1900 and 3800 rpm), and metal removal (no removal, two teeth on face mill, and six teeth on face mill). Mist concentration increased with increasing tool speed and fluid application velocity. Whether the tool was actually removing metal did not affect the mist generation. Thus, mist generation is a function of fluid and tool motion. During a second experiment, effect of tool speed and diameter on mist generation was studied. Mist concentrations measured with the aerosol spectrometer were proportional to the 2 and 3.5 powers of the tool speed for the face mill and end mill, respectively. In both experiments the shape of the size distribution was largely unaffected by the experimental variables. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0002-8894
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:22-30
-
Volume:61
-
Issue:1
-
NIOSHTIC Number:nn:20020693
-
Citation:Am Ind Hyg Assoc J 2000 Jan/Feb; 61(1):22-30
-
Contact Point Address:U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, 4676 Columbia Parkway--R5, Cincinnati, OH 45226
-
Federal Fiscal Year:2000
-
Peer Reviewed:True
-
Source Full Name:American Industrial Hygiene Association Journal
-
Collection(s):
-
Main Document Checksum:urn:sha-512:3a85b71fe9af37cc02f2b5b58ecc54f0674114ba8ea110226f2c131ee68ad8d540b222f4e4023bec7741c686b625b32bf5343e157796d67513af223c15ded839
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like