Description:Magnetic field characteristics have been surveyed systematically in six factories with the Multiwave II waveform capture instrument. These six facilities manufactured plastics, pharmaceuticals, cement, liquid air products, aluminum parts, and aluminum-framed filters. The study goals were to survey the physical characteristics of magnetic fields that may be related to biological effects under various interaction mechanisms and to relate those characteristics to the field's sources. From 59 waveform measurements at worker locations near sources, we calculated the extremely low frequency (ELF) and static field magnitudes, their frequency characteristics, and spatial characteristics of the 60Hz component. The RMS vector magnitude of the ELF magnetic field (the usual exposure metric in most studies) had medians ranging from 0.53 to 12.83microT in the six factories. The static magnetic field magnitudes had medians of 24.2-46.2microT, which is well below the geomagnetic reference field of 55.0microT because of shielding from steel structures. The maximum static field was 128.6microT near a DC motor. The frequency spectra of the most common fields is dominated by 60Hz, and has a median total harmonic distortion equal to 14.8%. The most common higher frequencies are the third, fifth, and second harmonics of 60Hz. However, magnetic fields in these workplaces had many other 60Hz harmonics and non-harmonic frequencies due particularly to electric motors and computer monitors. The 60Hz component magnetic fields have elliptical polarization with median axial ratio of 25.4%. The average proportion of the 60Hz component parallel to the static field vector was 51.5+/-3.0%, which indicates a significant trend towards perpendicular orientation between these two field components. In this survey of only six factories, the Multiwave II measurements documented a wide diversity of complex magnetic field characteristics and non-sinusoidal waveforms. Although these characteristics are important to the various mechanisms postulated to explain biological effects, they are overlooked by the popular exposure assessment methods which only measure the ELF magnitude. Therefore, spot measurements with the Multiwave II or similar waveform capture instruments are necessary for a complete magnetic field exposure assessment. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0003-4878
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Volume:44
-
Issue:8
-
NIOSHTIC Number:nn:20020619
-
Citation:Ann Occup Hyg 2000 Dec; 44(8):615-633
-
Contact Point Address:J. D. Bowman, National Institute for Occupational Safety and Health (Mail Stop C-27), 4676 Columbia Parkway, Cincinnati, OH 45226, USA
-
Email:jdbo@cdc.gov
-
Federal Fiscal Year:2001
-
Peer Reviewed:True
-
NAICS and SIC Codes:
-
Source Full Name:Annals of Occupational Hygiene
-
Collection(s):
-
Main Document Checksum:urn:sha-512:ea6e0ff255ee1466a11aabe2d7304cb8d593b19940a15a242046baf8b856116e36a2d311fcd10c38c5f0a94aefe550f157e1a9a39da1e8d55d7a944d9b7b289b
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like