Comparison of Six Respirator Fit-Test Methods with an Actual Measurement of Exposure in a Simulated Health Care Environment: Part III- Validation
Public Domain
-
1999/05/01
Details
-
Personal Author:
-
Description:This article, the last in a series of three, describes the validation phase of a study conducted to test the correlation of respirator fit factors to the subject's actual exposure using biological sampling. The study consisted of three phases: protocol development, method comparison testing, and validation. Six quantitative fit-test methods were evaluated in the method comparison testing phase. The two fit methods with the highest correlation with the wearers' measured exposure were a corn oil method (R2 = 0.81) and an ambient aerosol method (R2 = 0.78). Because the ambient aerosol method is more commonly used in the workplace, it was selected for further analysis. In this validation phase, the fit factors measured during the ambient aerosol fit-test were used to calculate the exposures to Freon-113 by using the model determined in the method comparison testing phase of the study. The actual Freon-113 exposures were then measured and compared with the predicted exposures. The results verified that the ambient aerosol method fit factors are highly correlated to the total Freon-113 exposure dose and thus that the model had a predictive ability. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0002-8894
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:363-366
-
Volume:60
-
Issue:3
-
NIOSHTIC Number:nn:20000832
-
Citation:Am Ind Hyg Assoc J 1999 May/Jun; 60(3):363-366
-
Contact Point Address:Christopher C. Coffey, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Division of Respiratory Disease Studies, 1095 Willowdale Road, Morgantown, WV 26505-2888
-
Federal Fiscal Year:1999
-
Peer Reviewed:True
-
Source Full Name:American Industrial Hygiene Association Journal
-
Collection(s):
-
Main Document Checksum:urn:sha-512:8fe050dff91b5b56d64c81ec31e53edbf1d16c279bd22bb3a66eb2bd4f65d1840f10d9f96d7593e4b5bbccc10e8c387d1fa6b9c75b7d4f839023afb29919436e
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like