The Effect of Glove Flexure on Permeation Parameters



Details

  • Personal Author:
  • Description:
    The impact of glove flexure on permeation by solvents was investigated. Neoprene gloves were tested with acetone (67641) and polyvinylchloride (PVC) gloves were tested with heptane (142825). The test cell consisted of a 1 gallon wide mouth jar containing 2 liters of the solvent. The subject's hand was layered with four gloves: the test glove, a woven mesh glove, a Silvershield glove, and a surgical glove. The gloves were tested during no flexing, and flexing periods of up to 2 hours. By examining a graph of weight versus time, the breakthrough detection time (BT) and steady state permeation rate (SSPR) were determined. For the PVC/heptane combination, the SSPRs ranged from 74 to 118 micrograms per minute per square centimeter (microg/min/cm2) for the static test and from 147 to 162microg/min/cm2 for a 5 minute (min) flex, and equaled 133microg/min/cm2 for a 1min flex. The BTs for the PVC/heptane combination ranged from 9 to 13min for the static test, from 5 to 8min for the 1min flex, and from 6 to 7min for the 5min flex. For the neoprene/acetone combination, the SSPRs ranged from 110 to 130microg/min/cm2 for the static test and from 151 to 171microg/min/cm2 for both the 1min and 5min flexes. The BTs for the neoprene/acetone combination ranged from 55 to 60min for the static test, from 43 to 46min for the 1min flex, and from 41 to 49min for the 5min flex. Although significant differences in BT and SSPR were detected between the static and flex runs of both combinations, no significant differences were observed between the 1min and 5min flex runs of either combination. The authors conclude that glove flexure may affect glove permeation. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    1047-322X
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Pages in Document:
    206-210
  • Volume:
    12
  • Issue:
    3
  • NIOSHTIC Number:
    nn:00235983
  • Citation:
    Appl Occup Environ Hyg 1997 Mar; 12(3):206-210
  • CAS Registry Number:
  • Federal Fiscal Year:
    1997
  • Performing Organization:
    Department of Environmental Health Sciences, School of Public Health, University of Alabama at Birmingham, Birmingham, Alabama
  • Peer Reviewed:
    True
  • Start Date:
    19930701
  • Source Full Name:
    Applied Occupational and Environmental Hygiene
  • End Date:
    19980630
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:348d92a46dacd5a3bbb309c364650b8ba1276bf33dbfcff387c36c303fd8bf56fa006997beb83acb395f4aaf90bf590ff6469351fae69614d78c0a5d6f93ac72
  • Download URL:
  • File Type:
    Filetype[PDF - 642.56 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.