Bias and Uncertainty of Penetrating Photon Dose Measured by Film Dosemeters in an Epidemiological Study of US Nuclear Workers
Public Domain
-
2005/03/15
Details
-
Personal Author:
-
Description:A retrospective exposure assessment of 1269 study subjects was completed for use in a multi-site case-control study of the relationship between protracted workplace external radiation exposure and leukaemia mortality. The majority of exposure data result from film badge monitoring programmes at the four US weapons production facilities and a US Naval shipyard. Bias and uncertainty in reported exposures among study facilities and across time were as result of differences in incident photon energy, exposure geometry, dosemeter type and dosimetry methods. These sources of measurement uncertainty were examined by facility and time to derive bias factors (B) for normalising exposures. In conjunction with facility reported results, the bias factors provide a means to estimate the equivalent dose, penetrating to a depth of 10 mm [H(p)(10)] and the equivalent dose to the active bone marrow for use in the epidemiological study. Uncertainty was expressed as the constructed 95% confidence interval (i.e. the 2.5th-97.5th% range) of the estimated parameter. The bias factors indicate that recorded exposures provide a reasonable estimate of H(p)(10) (bias factor near unity) and overestimate equivalent dose to active bone marrow (H(T)) by a factor between 1.2 and 1.7. On average, dosemeter-response uncertainties estimated using Monte Carlo simulation were approximately +/-19 and +/-33% for H(p)(10) and H(T), respectively. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0144-8420
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:275-289
-
Volume:113
-
Issue:3
-
NIOSHTIC Number:nn:20027056
-
Citation:Radiat Prot Dosimetry 2005 Mar; 113(3):275-289
-
Contact Point Address:Division of Surveillance, Hazard Evaluations, and Field Studies (DSHEFS), National Institute for Occupational Safety and Health (NIOSH), 5555 Ridge Avenue, R-44, Cincinnati, OH 45213, USA
-
Email:rtd2@cdc.gov
-
Federal Fiscal Year:2005
-
Peer Reviewed:True
-
Source Full Name:Radiation Protection Dosimetry
-
Collection(s):
-
Main Document Checksum:urn:sha-512:4d9c2d71d0e9c274550943e12f81e7ae41249b953f3a75674bac761bb46d7f28cd9478a40b2d3fb54dc552e1d05411caf41fbd89a9fc8bab4a98af0855a8ed32
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like