Folpet Permeation Through Nitrile Gloves



Details

  • Personal Author:
  • Description:
    The aim of this study was to investigate whether two different brands of unsupported and unlined nitrile gloves protected against aqueous emulsions of a Folpet wettable powder (50% Folpet) using an ASTM type-I-PTC 600 permeation cell at 30.0 +/- 0.1 degrees C held in a shaking water bath. An analytical method to determine Folpet using the internal standard method was first developed based on gas chromatography-mass spectrometry (GC-MS), and gas chromatography-electron capture detection (GC-ECD). A novel pyrolysis GC-ECD technique that quantified the thermal degradation product phthalimide had pg sensitivity suitable to detect the trace amounts of Folpet that permeated. The on-column conversion was (68.0 +/- 9.5) percent at 170 degrees C over the folpet injected mass range of 3 to 148 pg. The challenge solution in the permeation cell was 1.4 mg/mL aqueous emulsion of Folpet wettable powder, and 2-propanol was the collection solvent. After evaporation of the collection solvent, the time weighted average rate of permeation of Folpet through SafeSkin nitrile (an exams type of glove) after 8 hours was (42.1 +/- 2.9) ng/cm(2)/min compared with (2.04 +/- 0.69) ng/cm(2)/min for the Sol-Vex nitrile (industrial chemical resistant), the latter being about 21 times more protective and also near the limits of detection. The respective values after 4 hours of exposure were (28.4 +/- 1.2) and (0.65 +/- 0.36) ng/cm(2)/min. Diagnostic reflectance infrared minima of both challenge and collection sides of the gloves showed small changes in wave number and intensity values after 8 hours of exposure, with Folpet being detected in dried spots on the challenge side. GC-ECD-based permeation and IR reflectance data indicated high chemical resistance of the Sol-Vex gloves to an aqueous emulsion of Folpet. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    1047-322X
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Volume:
    18
  • Issue:
    9
  • NIOSHTIC Number:
    nn:20025552
  • Citation:
    Appl Occup Environ Hyg 2003 Sep; 18(9):658-668
  • Contact Point Address:
    Shane S. Que Hee, School of Public Health, University of California at Los Angeles, Los Angeles, California
  • CAS Registry Number:
  • Federal Fiscal Year:
    2003
  • Performing Organization:
    University of California Los Angeles
  • Peer Reviewed:
    True
  • Start Date:
    20000601
  • Source Full Name:
    Applied Occupational and Environmental Hygiene
  • End Date:
    20040531
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:60f44b730462a1f2375d6ba54dfbe5ade6b96d1352cdd316cb9cb5b247e4fb084d5b4e3342f3f4010eb4ee2e5e1cb38c2a31a1ce6ee3dcf8ac0a46d09e4997be
  • Download URL:
  • File Type:
    Filetype[PDF - 295.08 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.