Comparison of Mathematical Models for Exposure Assessment with Computational Fluid Dynamic Simulation
-
2000/01/01
-
Details
-
Personal Author:
-
Description:For many years exposure to airborne contaminants has been estimated by air or biological monitoring. In occupational settings, mathematical models increasingly are employed as adjuncts to monitoring, for instance, during process design or in retrospective epidemiological studies. Models can make predictions in a wide variety of scenarios, can be used for rapid screening, and may reduce the need for monitoring in exposure assessment. However, models make simplifying assumptions regarding air flow and contaminant transport. The errors resulting from these assumptions have not been systematically evaluated. Here we compare exposure estimates fromthe single-zone completely mixed (CM-1), two-zone completelymixed (CM-2), and uniform diffusivity (UD) models with workroom concentration fields predicted by computational fluid dynamics (CFD).The room air flow, concentration fields, and the breathing zone concentration of a stationary worker were computed using Fluent V4.3 for factorial combinations of three source locations, three dilution air flow rates and two emission rate profiles, constant and time-varying. These numerical experiments were used to generate plausible concentration fields, not to simulate exactly the processes in a real workroom. Thus, "error" is defined here as difference between model and CFD predictions. For both constant and time-varying emission sources, exposure estimates depended on receptor and source location. For the constant source case, ventilation rate was shown to be inconsequential to CM-1 model error. CM-1, CM-2, and UD models differed in their agreement with CFD. UD was closest to CFD for estimating concentration in the simulated breathing zone (BZ) near the source, although large errors resulted when the model was applied to the plane of possible breathing zones. CM-1 performed better for this plane but underestimated the near-source BZ exposure. For the near-source BZ location, CM-2 replicated CFD predictions more closely than CM-1 did, but less closely than UD did. Error in CM-1model estimation of short-term average exposure to a time-varying source was highly dependent on ventilation rate. Error decreased as ventilation rate increased. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:1047-322X
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:131-144
-
Volume:15
-
Issue:1
-
NIOSHTIC Number:nn:20025506
-
Citation:Appl Occup Environ Hyg 2000 Jan; 15 (1):131-144
-
Federal Fiscal Year:2000
-
Performing Organization:Arnold School of Public Health, University of South Carolina, Columbia
-
Peer Reviewed:True
-
Start Date:19940701
-
Source Full Name:Applied Occupational and Environmental Hygiene
-
End Date:20040630
-
Collection(s):
-
Main Document Checksum:urn:sha-512:1ede760b6afd1d4fd6ae37731548890d89155d85197d8be3bf5457ecdf0eb3f4dd9d6012101d7a0099e8102a4e8b4de601c6e08468f2802010c6c850b235f397
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like