Sampling efficiencies of three personal aerosol samplers within and beyond the inhalable particle size range

Public Domain


Details

  • Personal Author:
  • Description:
    A Simplified Test Protocol previously developed for the performance evaluation of personal inhalable aerosol samplers was used in a specially designed compact close-loop open-section wind tunnel. Traditional wind tunnels usually cannot handle particles larger than about 100 micrometers because rapid particle sedimentation makes it virtually impossible to achieve uniform aerosol distribution in the test zone. In contrast, the new wind tunnel facility was found useful for handling very large particles. The sampling efficiencies of three personal inhalable aerosol samplers (10M, GSP, and the Button Personal Aerosol Sampler) were measured with 65-, 96-, 165-, and 241 micrometer particles at four inlet orientations (0, 90, 180, and 270 degrees) to the wind of 50 and 100 cm/s velocity. Analysis of Variance (ANOVA) conducted on the data obtained with the 65-micrometer particles has indicated that there was no statistically significant difference in the samplers' performance when they are tested in the small and in the large wind tunnels following the Simplified Test Protocol and the conventional approach (samplers on a full-size human manikin). The data show that the sampling efficiency of the 10M sampler depends significantly on wind velocity and is above 100% for particles of 165 and 241 micrometer mass median aerodynamic diameter. This dependence is not statistically significant for the GSP and the Button Sampler, whose sampling efficiencies were similar to each other and do not change with increasing test particle size at the indicated wind velocities. Also, it was found that the sampling efficiencies of the GSP and the Button Sampler closely follow independent data obtained with a breathing rotating manikin at the wind velocity of 100 cm/s. Use of the new wind tunnel design is expected to enhance our ability to extend the inhalable convention beyond 100 micrometers. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • Publisher:
  • Document Type:
  • Genre:
  • Place as Subject:
  • CIO:
  • Division:
  • Topic:
  • Location:
  • Pages in Document:
    77
  • NIOSHTIC Number:
    nn:20041452
  • Citation:
    American Industrial Hygiene Conference and Exposition, June 2-7, 2001, New Orleans, Louisiana. Fairfax, VA: American Industrial Hygiene Association, 2001 Jun; :77
  • Federal Fiscal Year:
    2001
  • Peer Reviewed:
    False
  • Source Full Name:
    American Industrial Hygiene Conference and Exposition, June 2-7, 2001, New Orleans, Louisiana
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:145fb8ca1ce735aa6e1b6f071937b52b77e3322da73e1cfa2f86f616734ffa7822135af8a83513a6b0748cbf853f7d5f53aa43df34a39f5a881bce1aaa0e4301
  • Download URL:
  • File Type:
    Filetype[PDF - 178.33 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.