Isocyanate exposure assessments using the MAP method: a summary of recent NIOSH Health Hazard Evaluations
Public Domain
-
2001/06/02
Details
-
Personal Author:
-
Description:Background: NIOSH recently developed a sampling and analytical method for determining airborne exposures to isocyanate-containing compounds. The method's derivatizing agent is 1-(9-anthracenylmethyl) piperazine (MAP), which converts the isocyanate into a stable urea derivative. When sampling for isocyanates, air is drawn through a MAP impregnated filter, MAP-containing impinger, or impinger-filter combination, depending on the process and/or isocyanate species. The samples are analyzed by pH-gradient high pressure liquid chromatography with ultraviolet and fluorescence detection. Methods: The MAP method was recently used to evaluate airborne isocyanate exposures from four industrial operations. Three of these operations were spray painting, three were foam packaging, one was foam injection, and one was foam molding. The following isocyanates were used during these operations: hexamethylene diisocyanate (HDI), toluene diisocyanate (TDl), diphenylmethane diisocyanate (MDl), HDI-based polyisocyanates, MDl based polyisocyanates, and TDI prepolymer. Results: The range of exposures by operation and isocyanate species are shown below: Spray Painting: HDI - none detected (ND) to 1.9 micrograms per cubic meter (ug/m3), HDI polyisocyanate - ND to 164 ug/m3, MDl - 300 to 1364 ug/m3, MDI polyisocyanate - 304 to 1080 ug/m3, TDI - 5.1 to 9.6 ug/m3, and TDI prepolymer - 10.4 to 28.9 ug/m3. Foam Packaging: MDI - ND to 7.5 ug/m3, and MDI polyisocyanate - ND to 13.4 ug/m3. Foam Injection: MDI - ND to 5 ug/m3, and MDl polyisocyanate - ND to 38 ug/m3. Foam Molding: TDI - ND to 8.1 ug/m3. These facilities used various exposure and process emission controls to protect workers from potentially hazardous isocyanate exposures. An analysis of these control methods provides information on effective methods for controlling isocyanate exposures. Conclusion: The data from these evaluations demonstrate some of the advantages associated with the MAP method. This method is capable of measuring the different monomer and/or oligomer species used in a given process or formulation, and the improved sensitivity is especially useful when measuring short-term or task-based exposures. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:75
-
NIOSHTIC Number:nn:20041451
-
Citation:American Industrial Hygiene Conference and Exposition, June 2-7, 2001, New Orleans, Louisiana. Fairfax, VA: American Industrial Hygiene Association, 2001 Jun; :75
-
CAS Registry Number:
-
Federal Fiscal Year:2001
-
Peer Reviewed:False
-
Source Full Name:American Industrial Hygiene Conference and Exposition, June 2-7, 2001, New Orleans, Louisiana
-
Collection(s):
-
Main Document Checksum:urn:sha-512:dabf6b4a66ab17843f21482fdc5af7210eb4fdd25a24f528617b0c368b79567e3a3fc22a74a01e6aa5e2417c84d66ed7ff5ae3e68b86ff71294768e50d9ee474
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like