Implementation of an effective low cost engineering control for an HVAC related noise problem at a pediatric hospital
Public Domain
-
2001/06/02
-
Details
-
Personal Author:
-
Description:In follow-up to a request from hospital administration, evaluation of the noise being produced by the HVAC system which serves several executive offices located on the 5th floor of the Outpatient Services Building (OSB) was initiated in October 1999. Octave band and A- and C-weighted sound pressure level measurements were made at various locations in the fifth floor executive suite. The primary source of the noise in the executive suite is the HVAC unit which is located on the fifth floor in a mechanical room adjacent to the executive suite. The noise energy is produced by two different sources: the fan in the HVAC system, and the vibration of the supply duct(s) which transport air from the HVAC unit to the executive suite. The A-weighted (dBA) sound pressure level (SPL) readings collected throughout the entire office suite averaged 59.5 dB(A). While not considered to be hazardous under provisions of the OSHA standard, readings of this magnitude may constitute an annoyance in office environments because of the reduced ability to communicate effectively. ANSI addresses these concerns in a standard intended for evaluating room noise. Recommended sound pressure levels in executive office space are not to exceed 38 dB(A). Minor modifications in the fan operating parameters resulted in a significant noise reduction of 17 dBA (from 59.5 to 42.5 dBA). As a result, the work environment has improved, and the noise-related complaints from the office staff have ceased. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:60
-
NIOSHTIC Number:nn:20041425
-
Citation:American Industrial Hygiene Conference and Exposition, June 2-7, 2001, New Orleans, Louisiana. Fairfax, VA: American Industrial Hygiene Association, 2001 Jun; :60
-
Federal Fiscal Year:2001
-
Peer Reviewed:False
-
Source Full Name:American Industrial Hygiene Conference and Exposition, June 2-7, 2001, New Orleans, Louisiana
-
Collection(s):
-
Main Document Checksum:urn:sha-512:9cd2e7ea81672c3309bba66cc6f9c1319a1cfb05ad3c76d0410486b01b55626f6ee25924ae77dd46036b79aaeb0b86293e9d655ca7964438d20b4edfe906ff24
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like