Environmental assessment of a reference mycobacteriology laboratory and five public hospitals in Mexico with regard to occupationally-acquired tuberculosis
Public Domain
-
2001/06/02
Details
-
Personal Author:
-
Description:In 1998, NlOSH responded to two separate requests for technical assistance from the Mexican National Institute of Diagnostics and Reference Epidemiology and the Mexican National Institute for Public Health to environmentally evaluate the federal reference mycobacteriology laboratory, five public hospitals, a primary care clinic, and a university research laboratory, all distally located across the nation. Specifically, the requests were concerned with environmental factors that could contribute to occupational exposures to Mycobacterium tuberculosis. On-site surveys were conducted that included observational assessment, smoke visualization to characterize air flow patterns, and measurements, where applicable, for air flow, air static pressure, and particle counts to quantify containment parameters. Measurements were also made of the energy produced by ultraviolet germicidal irradiation (UVGI) lamps. For the reference mycobacteriology laboratory, deficiencies included inappropriate pressure relationships between adjacent areas (including the operation of the Biosafety Level 3 facility); the use of fume hoods as biological safety cabinets with inadequate exhaust; inappropriate respiratory protection; and the lack of a comprehensive UVGI program that includes interlocks, employee training, and preventive maintenance. For the hospitals, assessments were focused in areas where patients suspected of active tuberculosis may reside, such as the emergency room, the outpatient clinic, radiology, surgical recovery, the intensive care unit, and the bacteriology laboratory (where specimens from active patients may be sent for analysis). The level of environmental controls varied with the financial sponsorship of the hospitals, e.g., from natural ventilation to ventilation systems installed with high-efficiency particulate air filtration. Other control deficiencies included the lack of appropriate respiratory protection, improper pressure relationships between adjacent areas, poor isolation procedures (including poor isolation room design), and the lack of appropriate biological safety cabinets. Recommendations were made at the conclusion of each site visit that could be practically implemented, economically, given limited resources, and within a reasonable time frame. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:5
-
NIOSHTIC Number:nn:20041347
-
Citation:American Industrial Hygiene Conference and Exposition, June 2-7, 2001, New Orleans, Louisiana. Fairfax, VA: American Industrial Hygiene Association, 2001 Jun; :5
-
Federal Fiscal Year:2001
-
Peer Reviewed:False
-
Source Full Name:American Industrial Hygiene Conference and Exposition, June 2-7, 2001, New Orleans, Louisiana
-
Collection(s):
-
Main Document Checksum:urn:sha-512:1a555d9dccaaa17f427433b243d3f937ff8f05d72462a05a81169ebade4e621794be1e0c12f549ff6b217107e2ef6f73187da1cdd72452518c401c496cf9b9b8
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like