Postural sway measurements: a potential safety monitoring technique for workers wearing personal protective equipment
-
2002/04/01
-
Details
-
Personal Author:
-
Description:This study investigated the use of postural sway measurements as a potential safety monitoring technique. Sixteen healthy male volunteers (age: 41.8 +/- 9.3 years) participated in this study. The level of neurophysiological strain and the ability to maintain upright balance for workers wearing personal protective equipment (PPE) were investigated. Three levels of PPE, the United States Environmental Protection Agency (USEPA)-defined levels A, B, and C, were worn in random order while performing two randomly ordered tasks, resting and a workload. After the workload task, the perceived exertion and discomfort were recorded. Postural sway, measured using a microprocessor-based force platform system, was assessed after each task. The variables of sway area and sway length were calculated from stabilograms. These measurements were taken for three sway tests: 1) Eyes open (EO), 2) Eyes closed on a four-inch foam (FC), and 3) a dynamic test with the subject reaching for a weight placed in front, lifting it to his chest, and lowering back to the shelf four times (RE). The heart rate was significantly higher for the workload task (p < 0.05), and the levels A and B PPE demonstrated significantly higher perceived exertion results than level CPPE (p<0.05). The heart rate and perceived exertion were not significantly correlated with the sway measurements. Level A produced significant self-reported discomfort results for the upper back, lower back, and thighs. The sway variables showed significant differences with the PPE levels and the task. The workload task produced significantly higher sway length than the resting task (p < 0.05) for all test conditions. The PPE level B produced significantly higher sway length than PPE level A (p < 0.05) in the FC test condition. These results indicate that postural stability is altered with PPE use and with fatigued postural muscles. In summary, postural sway measurements may be used as a potential safety monitoring technique. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:1047-322X
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:256-266
-
Volume:17
-
Issue:4
-
NIOSHTIC Number:nn:20041067
-
Citation:Appl Occup Environ Hyg 2002 Apr; 17(4):256-266
-
Contact Point Address:Laurel D. Kincl, Department of Environmental Health, College of Medicine, University of Cincinnati, Cincinnati, OH 45267-0056
-
Federal Fiscal Year:2002
-
Performing Organization:University of Cincinnati
-
Peer Reviewed:True
-
Start Date:19920701
-
Source Full Name:Applied Occupational and Environmental Hygiene
-
End Date:20070630
-
Collection(s):
-
Main Document Checksum:urn:sha-512:fba353010d552e2d95e189d45146673de095ff2af0329b839986351765e6029d635cafbbe34e8442ab4311b9245905fb46d35d598b83f0843f297f5bfce58259
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like