An analysis of contact stiffness between a finger and an object when wearing an air-cushioned glove: the effects of the air pressure
Public Domain
-
2012/04/01
-
Details
-
Personal Author:
-
Description:Air-cushioned gloves have the advantages of lighter weight, lower cost, and unique mechanical performance, compared to gloves made of conventional engineering materials. The goal of this study is to analyze the contact interaction between fingers and object when wearing an air-cushioned glove. The contact interactions between the the fingertip and air bubbles, which is considered as a cell of a typical air-cushioned glove, has been analyzed theoretically. Two-dimensional finite element models were developed for the analysis. The fingertip model was assumed to be composed of skin layers, subcutaneous tissue, bone, and nail. The air bubbles were modeled as air sealed in the container of nonelastic membrane. We simulated two common scenarios: a fingertip in contact with one single air bubble and with two air cushion bubbles simultaneously. Our simulation results indicated that the internal air pressure can modulate the fingertip-object contact characteristics. The contact stiffness reaches a minimum when the initial air pressure is equal to 1.3 and 1.05 times of the atmosphere pressure for the single air bubble and the double air bubble contact, respectively. Furthermore, the simulation results indicate that the double air bubble contact will result in smaller volumetric tissue strain than the single air bubble contact for the same force. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:1350-4533
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:386-393
-
Volume:3
-
Issue:4
-
NIOSHTIC Number:nn:20039638
-
Citation:Med Eng Phys 2012 Apr; 3(4):386-393
-
Contact Point Address:John Z. Wu, Engineering & Control Technology Branch, National Institute for Occupational Safety and Health, 1095 Willowdale Road, Morgantown, MS L-2027, WV 26505
-
Email:ozw8@cdc.gov
-
Federal Fiscal Year:2012
-
Peer Reviewed:True
-
Source Full Name:Medical Engineering & Physics
-
Collection(s):
-
Main Document Checksum:urn:sha-512:35c4e56bdaa935f42bf926ca07b9d02adaa7fd7b41baa06e968a97af392a4acb031d810a96ddbd87529854605f28378f40611b9af9379c5b18f1643dc39e41f9
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like