Evaluation of an artificial intelligence program for estimating occupational exposures
-
2005/03/01
-
Details
-
Personal Author:
-
Description:Estimation and Assessment of Substance Exposure (EASE) is an artificial intelligence program developed by UK's Health and Safety Executive to assess exposure. EASE computes estimated airborne concentrations based on a substance's vapor pressure and the types of controls in the work area. Though EASE is intended only to make broad predictions of exposure from occupational environments, some occupational hygienists might attempt to use EASE for individual exposure characterizations. This study investigated whether EASE would accurately predict actual sampling results from a chemical manufacturing process. Personal breathing zone time-weighted average (TWA) monitoring data for two volatile organic chemicals--a common solvent (toluene) and a specialty monomer (chloroprene)--present in this manufacturing process were compared to EASE-generated estimates. EASE-estimated concentrations for specific tasks were weighted by task durations reported in the monitoring record to yield TWA estimates from EASE that could be directly compared to the measured TWA data. Two hundred and six chloroprene and toluene full-shift personal samples were selected from eight areas of this manufacturing process. The Spearman correlation between EASE TWA estimates and measured TWA values was 0.55 for chloroprene and 0.44 for toluene, indicating moderate predictive values for both compounds. For toluene, the interquartile range of EASE estimates at least partially overlapped the interquartile range of the measured data distributions in all process areas. The interquartile range of EASE estimates for chloroprene fell above the interquartile range of the measured data distributions in one process area, partially overlapped the third quartile of the measured data in five process areas and fell within the interquartile range in two process areas. EASE is not a substitute for actual exposure monitoring. However, EASE can be used in conditions that cannot otherwise be sampled and in preliminary exposure assessment if it is recognized that the actual interquartile range could be much wider and/or offset by a factor of 10 or more. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0003-4878
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:147-153
-
Volume:49
-
Issue:2
-
NIOSHTIC Number:nn:20039035
-
Citation:Ann Occup Hyg 2005 Mar; 49(2):147-153
-
Contact Point Address:Margaret L. Phillips; Department of Occupational and Environmental Health, College of Public Health, University of Oklahoma Health Sciences Center, 801 N.E. 13th Street, Oklahoma City, OK 73104
-
Email:margaret-phillips@ouhsc.edu
-
Federal Fiscal Year:2005
-
Performing Organization:University of Illinois at Chicago
-
Peer Reviewed:True
-
Start Date:20050701
-
Source Full Name:Annals of Occupational Hygiene
-
End Date:20290630
-
Collection(s):
-
Main Document Checksum:urn:sha-512:4308dac4e3827625d1c2198c7beeee40b37b8eb85eaa6c7a7f0a9a3556a07f0de8e50ef937598074e649362f338a37d39aa0e01115b0b814e20ce4859515e5da
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like