Heat and humidity buildup under earmuff-type hearing protectors
Public Domain
-
2011/03/01
Details
-
Personal Author:
-
Description:A major barrier to effective wear of hearing protection is comfort. This study examined several comfort indicators in the earmuff-type hearing protectors. Twenty subjects wore hearing protectors instrumented with two different temperature/humidity measurement systems (Omega and iButton) while walking a corridor for about 25 min. The instruments recorded the temperature and humidity every 10 s and their results were compared. In addition, skin surface pH was measured at the ear canal entrance before and after the task. Finally, the subject indicated earmuff comfort at the beginning and end of the session. Earmuff comfort decreased significantly over the course of the walking task. Ear canal pH became slightly less acidic, but the change was not statistically significant. The two temperature/humidity systems provided comparable results. Heat increased at about 0.3 degrees F while humidity built up at about 0.5%/min. However, the study found some limitations on the instrumentation. The complexity of the electrical connections and equipment in the Omega probe system led to loss of three subject's data. The iButton device was more robust, but provided only 256 gradations of temperature and relative humidity. Even with its limitations, the iButton device would be a valuable tool for field studies. The present study showed that the buildup of heat and humidity can be modeled using linear equations. The present study demonstrates that relatively inexpensive tools and a low-exertion task can provide important information about the under-earmuff environment, which can inform assumptions about comfort during use. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:1463-1741
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:93-98
-
Volume:13
-
Issue:51
-
NIOSHTIC Number:nn:20038399
-
Citation:Noise Health 2011 Mar-Apr; 13(51):93-98
-
Contact Point Address:Rickie Davis, NIOSH-Taft Laboratories, Hearing Loss Prevention Team, 4676 Columbia Parkway, Cincinnati, OH 45226-1998, USA
-
Email:RDavis@cdc.gov
-
Federal Fiscal Year:2011
-
NORA Priority Area:
-
Peer Reviewed:True
-
Source Full Name:Noise & Health
-
Collection(s):
-
Main Document Checksum:urn:sha-512:f2d05fc0a164b3cd2e5840e85242b3364f798094e41f426442c6823632271c7fc03cc0837cb887548a9f02ef78e88f772926ecb7ebf0e2fd971f85ba3bf15c8f
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like