Sharpless surgery: a prospective study of the feasibility of performing operations using non-sharp techniques in an urban, university-based surgical practice
-
2006/07/01
-
Details
-
Personal Author:Baker SP ; Chang D ; Cornwell EE 3rd ; Freischlag JA ; Makary MA ; Millman EA ; Pronovost PJ ; Syin D ; Weiss, Eric S.
-
Description:CONTEXT: Percutaneous injuries occur frequently during surgical procedures and represent a significant occupational hazard to operating room personnel. OBJECTIVES: To evaluate the feasibility of performing select general surgical procedures using a combination of non-sharp devices and techniques to replace the conventional use of scalpels and needles. DESIGN, SETTING, AND PARTICIPANTS: Candidate procedures for which sharpless techniques could replace conventional scalpels and suture needles were identified preoperatively in an urban, university-based general surgical practice over a 1-year period (June 2003-June 2004). Non-sharp techniques included monomeric 2-octyl cyanoacrylate adhesive, electrocautery, tissue stapler, and minimally invasive instrumentation. Conventional scalpels and suture needles were readily available and used whenever necessary. MAIN OUTCOME MEASURES: We rated the feasibility of performing specific procedures without sharps. We also documented the rate of overall reversion to sharps during operations on patients that had been identified preoperatively as candidates for sharpless surgery. RESULTS: Of 358 procedures performed in the general surgery university practice, 91 were identified preoperatively as appropriate for sharpless surgery. Of these, 86.8% (79/91) were completed without the use of sharps, including 13/22 (59.1%) open laparotomy procedures, 20/22 (90.9%) laparoscopic procedures, and 46/47 (97.8%) soft tissue procedures. Intraoperative reversion to sharps occurred in 12 cases when deemed necessary by the surgeon. CONCLUSIONS: Select common procedures can be performed entirely with sharpless techniques, eliminating the risk to surgical personnel associated with intraoperative percutaneous injuries. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0364-2313
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Volume:30
-
Issue:7
-
NIOSHTIC Number:nn:20037868
-
Citation:World J Surg 2006 Jul; 30(7):1224-1229
-
Contact Point Address:Martin A. Makary, Department of Surgery, John Hopkins University School of Medicine, Johns Hopkins Medical Institutions, Baltimore, Maryland 21224, USA
-
Email:mmakary1@jhmi.edu
-
Federal Fiscal Year:2006
-
Performing Organization:Johns Hopkins University
-
Peer Reviewed:True
-
Start Date:20050701
-
Source Full Name:World Journal of Surgery
-
End Date:20280630
-
Collection(s):
-
Main Document Checksum:urn:sha-512:89bca6f3e3fc285f91d44d94fb036dfbf6683ebdb5d0fb562fb31f0bb8e309e75378c6e2a7b1b4447aacad340952e6eb889d5a58c63dfe687c3e640feb0e9820
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like