Efficiency of Respirator Filters Against Nano-Aerosols Under High Flow Conditions
Public Domain
-
2005/10/03
-
Details
-
Personal Author:
-
Description:Respirators are routinely used in the workplace to protect against a variety of airborne particulate contaminants. The filtration efficiency of particulate respirators are certified by the National Institute for Occupational Safety and Health (NIOSH) at a constant flow rate of 85 L/min using salt and oil test aerosols having a mass median diameter (MMD) of approximately 300 nm. However, measurements of physiological parameters of workers show peak inhalation flow rates for short durations in excess of 400 L/min for certain activities that demand high work loads. This study investigated the respirator filter efficiency against nano-aerosols (20 to100 nm MMD), which are potential particulate exposure hazards associated with nanotechnology, and larger size aerosol particles (MMD >100 nm) produced in traditional industrial workplace settings. The filtration efficiencies of NIOSH-approved P100 and N95 particulate respirator filtering facepiece masks and cartridge filters were measured at high volumetric and peak flow rates. Four cyclic flow conditions (40, 85, 115, and 135 L/min minute volume) with peak flows up to 430 L/min and three constant flow rates (85, 270, and 360 L/min) were evaluated. As expected, aerosol penetration was found to increase with increased cyclic and constant flow rate. The magnitude and significance of this increase was dependent on the specific filter type and design. The most penetrating particle size was generally between 100 and 200 nm for the P100 cartridge filters and 50 and 100 nm for the N95 cartridge filters and all filtering facepiece masks. In general, the filters met the penetration requirements for N95 and P100 filters for all particle sizes tested at a constant flow of 85 L/min. However, nano-aerosol penetrations in excess of 0.03 % and 5.0 % for the P100 and N95 filters, respectively, were observed at constant and cyclic flow conditions above 85 L/min. Comparison of the penetrations measured under cyclic and constant flow indicates that the mean and peak inhalation flow rates are important parameters to consider when evaluating filtration performance. For the P100 and N95 cartridge filters, similar penetrations were measured under constant and cyclic flow if the constant flow was equivalent to the mean inhalation flow rate. The penetrations measured at constant flow rates equivalent to the peak inhalation flow under cyclic flow conditions tended to provide a more conservative estimate of filter performance. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:57
-
NIOSHTIC Number:nn:20029969
-
Citation:2nd International Symposium on Nanotechnology and Occupational Health, October 3-6, 2005, Minneapolis, Minnesota. Minneapolis, MN: University of Minnesota, 2005 Oct; :57
-
Contact Point Address:National Personal Protective Technology Laboratory, NIOSH, 626 Cochrans Mill Road, Pittsburgh, PA 15236
-
Federal Fiscal Year:2006
-
Peer Reviewed:False
-
Source Full Name:2nd International Symposium on Nanotechnology and Occupational Health, October 3-6, 2005, Minneapolis, Minnesota
-
Collection(s):
-
Main Document Checksum:urn:sha-512:de4dd8bf9307ce0abe0f309f7343d356dd6def160a18fb2db9e1c0895f8a1db147de122c08c59d56ff498e4ddc4bf07e2a4c6d5d569ac681ee9667321f3bd366
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like