U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Development of a Personal Sampling Setup for Assessing the Efficiency of Respirators Against Fungal Spores



Details

  • Personal Author:
  • Description:
    In this study, we have developed and evaluated a new personal setup for determining the efficiencies of respirators by simultaneously collecting fungal spores and non-biological particles inside and outside N95 filtering facepiece respirators. The setup was optimized by minimizing the particle losses in the aerosol transmission system. The theoretical modeling and laboratory tests were performed for the design optimization. The setup consists of seven components: sampling probe, tubing, sampling chamber, optical particle counter, 25-mm cassette with a polycarbonate filter, flowmeter, and the sampling pump. The theoretical calculation, which included the aerosol deposition mechanisms such as gravitation, inertia, turbulence, and losses in bending, were modeled for three tubing diameters (1/8", 1/4" and ½") and two tubing placements (when it was directed respectively above the ear and the shoulder). The aerosol transmission through the tubing was estimated for the particle size range of 0.7-5 microm, which includes most airborne fungal spores. Since the theoretical values of the transmission efficiency were almost zero for the tubing of 1/8" if the particle size exceeded 3microm, only tubings of 1/4" and ½" were selected for the laboratory experiments. The laboratory study was performed in a walk-in chamber with sodium chloride particles sampling through two sampling lines. One was used to measure the ambient aerosol concentrations and the other to measure the concentrations at the tubing outlet. The ratio of the aerosol concentrations measured with two sampling lines was defined as the transmission efficiency. For the size range of 3-5 microm, the experimental transmission efficiencies were 77% (ear) and 83% (shoulder) for 1/4" tubing. The theoretical values were lower, which can be attributed to particle bounce/reentrainment not accounted for by the theory. For 1/2" tubing, the experimental efficiencies were 77% (ear) and 71% (shoulder). These agreed well with the theoretical data. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • Publisher:
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Pages in Document:
    1
  • NIOSHTIC Number:
    nn:20028937
  • Citation:
    American Industrial Hygiene Conference and Exposition, May 10-15, 2003, Dallas, Texas. Fairfax, VA: American Industrial Hygiene Association, 2003 May; :1
  • Federal Fiscal Year:
    2003
  • NORA Priority Area:
  • Performing Organization:
    University of Cincinnati
  • Peer Reviewed:
    False
  • Start Date:
    20010601
  • Source Full Name:
    American Industrial Hygiene Conference and Exposition, May 10-15, 2003, Dallas, Texas
  • End Date:
    20110731
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:012280e59510bbb31f0642a84748808c0392c4a662cd0e52c7b3f10720547d412c5d62ff3d37540679d90bf6f7ad500ec481d7d0d60519171c50f6b9e5133d49
  • Download URL:
  • File Type:
    Filetype[PDF - 205.00 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.