Development of a New Method for Measuring the Protection Provided by Respirators Against Dust and Microorganisms
-
2004/06/01
-
Details
-
Personal Author:
-
Description:The efficiency of respirators is usually determined by the protection factor, which is the ratio of the particle concentration outside the respirator to that inside the respirator. Most studies on workplace protection factors (WPF) of respirators have focused on the measurement of total mass concentrations, ignoring the effect of particle size. Furthermore, there appear to be on previous studies on protection factors against biological particles. In this study, a prototype personal sampling setup was developed for determining the protection provided by respirators again non-biological and biological particles in the size rang of 0.7-10 um. The range covers respirable and thoracic dust particles as well as most bacterial and fungal spores. The setup is compatible for field use in workplace environments and was optimized by minimizing particle losses in its aerosol transmission system. Theoretical modeling, laboratory tests, and field tests were performed for design optimization. After accounting for aerosol deposition mechanisms due to gravity, inertia, and turbulence affecting aerosol transmission through the straight and bending sections of specialized tubing, the theoretical data showed best agreement with the laboratory and field data for a tube diameter of 1/2 inch (approximately 1.27 com) among the three tested diameters. Tubing of this diameter also had the least amount of particle losses, and can be directed either above the ear or above the shoulder of the person whose respiratory protection is being evaluated. In addition, the ability of the setup to measure the WPF when a human subject donned a respirator was demonstrated successfully during soybean unloading. This study suggests that the new setup is a promising tool for future studies on evaluating respiratory protection against airborne dusts and microorganisms in occupational environments. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:1680-8584
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:56-73
-
Volume:4
-
Issue:1
-
NIOSHTIC Number:nn:20028936
-
Citation:Aerosol Air Qual Res 2004 Jun; 4(1):56-73
-
Contact Point Address:Tiina Reponen, Center for Health-Related Aerosol Studies, Department of Environmental Health, University of Cincinnati, P.O. Box 670056, Cincinnati, OH 45267-0056, USA
-
Email:Tiina.Reponen@uc.edu
-
Federal Fiscal Year:2004
-
NORA Priority Area:
-
Performing Organization:University of Cincinnati
-
Peer Reviewed:True
-
Start Date:20010601
-
Source Full Name:Aerosol and Air Quality Research
-
End Date:20110731
-
Collection(s):
-
Main Document Checksum:urn:sha-512:ccb3481aa21d13fe539c849c24808374b2c41c3bf5c3fd79c21ad75047db950605267bfbfe048041e48577cc839bb433a785c181b9e5fd1f7e77227dfbd88694
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like