Carbon Nanotube-Based Electrochemical Sensor for Cholinesterase Enzyme Activity: An Organophosphorus Insecticide and Nerve Agent Exposure Monitor
-
2008/03/01
-
Details
-
Personal Author:
-
Description:Simple, rapid and sensitive analytical sensors are needed to evaluate exposures to organophosphorus insecticides and nerve agents utilizing readily obtainable biological fluids, like saliva. An electrochemical sensor coupled with a micro-flow injection system was developed to characterize cholinesterase (ChE) enzyme activity. The sensor is based on a carbon nanotube (CNT)-modified screen-printed carbon electrode (SPE) integrated into a flow cell. The electrocatalytic activity of the carbon nanotubes, enable the sensor to detect electroactive species that are produced from enzymatic reactions with high sensitivity. The electrochemical properties of ChE enzymatic products were studied using the sensor, and the operation parameters such as the applied potential and substrate concentration were optimized. ChE activity was further investigated using the CNT-based sensor with purified human acetylcholinesterase (AChE) and in vitro with saliva obtained from naive rats. For purified AChE the calibration curve was linear over a range of concentrations (5 pM to 0.5 nM) and the detection limit was estimated to be approximately 2 pM. The dynamics of salivary ChE activity was also studied in vitro. Paraoxon (0.7 nM and 7 nM) was mixed with 10-fold diluted saliva (1:1 v/v) and incubated for different time periods (5 to 120 min) then 100 microL of the mixed solution was reacted with an equal volume of 5 mM acetylthiocholine (approximately 10 min) and sequentially assayed with the sensor. A concentration-dependent inhibition of salivary ChE activity was observed. At 0.7 nM paraoxon, the sensor response indicated approximately 80% enzyme inhibition within 0.5 h; whereas, at 7 nM 100% inhibition was achieved. Future studies will evaluate the sensor performance following in vivo exposure of rats to ChE inhibiting pesticides. This new CNT-based electrochemical sensor represents a potential next generation sensor for noninvasive biomonitoring of exposure to OP insecticides and chemical nerve agents. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:1096-6080
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Volume:102
-
Issue:1
-
NIOSHTIC Number:nn:20033641
-
Citation:Toxicologist 2008 Mar; 102(1):360
-
Federal Fiscal Year:2008
-
NORA Priority Area:
-
Performing Organization:Battelle Pacific Northwest Laboratories
-
Peer Reviewed:False
-
Start Date:20060901
-
Source Full Name:The Toxicologist. Society of Toxicology 47th Annual Meeting and ToxExpo, March 16-20, 2008, Seattle, Washington
-
End Date:20170831
-
Collection(s):
-
Main Document Checksum:urn:sha-512:7e4e674ff32b252c65b633c12b8a0cbe71ef0cd451be6c010f8505e8cd0483f7989243a0bd0d3d9738e1ffc545bb61390489162eb12f4c5b1dc607c503ce133a
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like