Contribution of Facial Feature Dimensions and Velocity Parameters on Particle Inhalability
-
2010/08/01
Details
-
Personal Author:
-
Description:To examine whether the actual dimensions of human facial features are important to the development of a low-velocity inhalable particulate mass sampling criterion, this study evaluated the effect of facial feature dimensions (nose and lips) on estimates of aspiration efficiency of inhalable particles using computational fluid dynamics modeling over a range of indoor air and breathing velocities. Fluid flow and particle transport around four humanoid forms with different facial feature dimensions were simulated. All forms were facing the wind (0.2, 0.4 m s-1), and breathing was simulated with constant inhalation (1.81, 4.3, 12.11ms-1). The fluid flow field was solved using standard k-epsilon turbulence equations, and laminar particle trajectories were used to determine critical areas defining inhaled particles. The critical areas were then used to compute the aspiration efficiency of the mouth-breathing humanoid. One-tailed t-tests indicated that models with larger nose and lip features resulted in significantly lower aspiration efficiencies than geometries with smaller features, but the shape of the orifice into the mouth (rounded rectangle versus elliptical) had no effect on aspiration efficiency. While statistically significant, the magnitudes of differences were small: on average, the large nose reduced aspiration efficiency by 6.5% and the large lips reduced aspiration efficiency by 3.2%. In comparison, a change in breathing velocity from at-rest to heavy increased aspiration efficiency by an average of 21% over all particle sizes, indicating a much greater impact of aspiration efficiency on breathing rate in the facing-the-wind orientation. Linear regression models confirmed that particle diameter and breathing velocity were significant predictors to the aspiration fraction, while the facial feature dimensions were not significant contributors to a unifying model. While these effects may be less pronounced as the orientation changes from facing-the-wind, their impact confirms the importance of breathing velocity and, to a lesser extent, facial feature dimensions on exposure estimates in low freestream velocities typical of occupational environments. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0003-4878
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Volume:54
-
Issue:6
-
NIOSHTIC Number:nn:20037285
-
Citation:Ann Occup Hyg 2010 Aug; 54(6):710-725
-
Contact Point Address:T. Renée E Anthony, Department of Occupational and Environmental Health, University of Iowa, 100 Oakdale Campus, 108 IREH, Iowa City, IA 52242-5000, USA
-
Email:reneeanthony@uiowa.edu
-
Federal Fiscal Year:2010
-
Performing Organization:University of Iowa
-
Peer Reviewed:True
-
Start Date:20080601
-
Source Full Name:Annals of Occupational Hygiene
-
End Date:20130531
-
Collection(s):
-
Main Document Checksum:urn:sha-512:30381fed81aea0b3eb92d006f447671075f5832ebe700100a6dcb6ac05329c434b03c0d39adf88c83e04622f54d3695abec6c703822db1ce7072c400bab1656c
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like