A System for Recording High Fidelity Cough Sound and Airflow Characteristics
Public Domain
-
2010/02/01
-
Details
-
Personal Author:
-
Description:Cough is considered an early sign of many respiratory diseases. Recently, there has been increased interest in measuring, analyzing, and characterizing the acoustical properties of a cough. In most cases the main focus of those studies was to distinguish between involuntary coughs and ambient sounds over a specified time period. The objective of this study was to develop a system to measure high fidelity voluntary cough sounds to detect lung diseases. To further augment the analysis capability of the system, a non-invasive flow measurement was also incorporated into the design. One of the main design considerations was to increase the fidelity of the recorded sound characteristics by increasing the signal to noise ratio of cough sounds and to minimize acoustical reflections from the environment. To accomplish this goal, a system was designed with a mouthpiece connected to a cylindrical tube. A microphone was attached near the mouthpiece so that its diaphragm was tangent to the inner surface of the cylinder. A pneumotach at the end of the tube measured the airflow generated by the cough. The system was terminated with an exponential horn to minimize sound reflections. Custom software was developed to read, process, display, record, and analyze cough sound and airflow characteristics. The system was optimized by comparing acoustical reflections and total signal to background noise ratios across different designs. Cough measurements were also collected from volunteer subjects to assess the viability of the system. Results indicate that analysis of cough characteristics has the potential to detect lung disease. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0090-6964
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:469-477
-
Volume:38
-
Issue:2
-
NIOSHTIC Number:nn:20036471
-
Citation:Ann Biomed Eng 2010 Feb; 38(2):469-477
-
Contact Point Address:W. T. Goldsmith, National Institute for Occupational Safety and Health, Health Effects Laboratory Division, Pathology and Physiology Research Branch, 1095 Willowdale Road, Morgantown, WV 26505, USA
-
Email:wbg4@cdc.gov
-
Federal Fiscal Year:2010
-
Peer Reviewed:True
-
Source Full Name:Annals of Biomedical Engineering
-
Collection(s):
-
Main Document Checksum:urn:sha-512:9552afa96452b5925fa84249a1a411d7ee6af29081cf95c730c0ceaf2f522e7623b9b351dad557ca1b85d745f6eae9f7bfe2fee1a86700f6f9501da81ad1df39
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like