U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Influence of Advanced Electromyogram (EMG) Amplitude Processors on EMG-to-Torque Estimation During Constant-Posture, Force-Varying Contractions



Details

  • Personal Author:
  • Description:
    Numerous studies have investigated the relationship between surface electromyogram (EMG) and torque exerted about a joint. Most studies have used conventional EMG amplitude (EMGamp) processing, such as rectification followed by low-pass filtering, to pre-process the EMG before relating it to torque. Recently, advanced EMGamp processors that incorporate signal whitening and multiple-channel combination have been shown to significantly improve EMGamp processing. In this study, we compared the performance of EMGamp-torque estimators with and without these advanced EMGamp processors. Fifteen subjects produced constant-posture, non-fatiguing, force-varying contractions about the elbow while torque and biceps/triceps EMG were recorded. EMGamp was related to torque using a linear FIR model. Both whitening and multiple-channel combination reduced EMG-torque errors and their combination provided an additive benefit. Using a 15th-order linear FIR model, EMG-torque errors with a four-channel, whitened processor averaged 7.3% of maximum voluntary contraction (MVC) (or 78% of variance accounted for). By comparison, the equivalent single-channel, unwhitened (conventional) processor produced an average error of 9.9% of MVC (variance accounted for of 55%). In addition, the study describes the occurrence of spurious peaks in estimated torque when the torque model is created from data with a sampling rate well above the bandwidth of the torque. This problem occurs when the torque data are sampled at the same rate as the EMG data. The problem is corrected by decimating the EMGamp prior to relating it to joint torque, in our case to an effective sampling rate of 40.96 Hz. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    0021-9290
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Volume:
    39
  • Issue:
    14
  • NIOSHTIC Number:
    nn:20031437
  • Citation:
    J Biomech 2006 Nov; 39(14):2690-2698
  • Contact Point Address:
    Department of Electrical and Computer Engineering, Department of Biomedical Engineering, Worcester Polytechnic Institute, 100 Institute Rd., Worcester, MA 01609
  • Email:
    ted@wpi.edu
  • Federal Fiscal Year:
    2007
  • Performing Organization:
    Worcester Polytechnic Institute
  • Peer Reviewed:
    True
  • Start Date:
    20030915
  • Source Full Name:
    Journal of Biomechanics
  • End Date:
    20060914
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:0f0a3f380b655196d9fde71556706db736dce160a976d7c179d0c235dfc427e6aed213b50d43597c92424670e2973493635662b6ed5bfa4182662952ac558ebe
  • Download URL:
  • File Type:
    Filetype[PDF - 347.78 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.