Description:A test system to evaluate sampling error associated with in facepiece sampling of half mask respirators was described. Sample mixing within the facepiece cavity was assessed in a screening experiment utilizing a fixed effect 3k factorial design and an in facepiece sampling technique used to conduct quantitative facepiece fit testing. The factors for analysis included sampling probe location, sampling probe depth, leak site on the faceseal perimeter, breathing distribution patterns, and measurement sample rate. The equations used to predict the actual concentration of sample within the facepiece cavity were described in detail. The sample tested was acetone (67641), and the predicted and measured concentrations in the facepiece cavity were compared according the the equations presented and a test apparatus consisting of an acetone generation and storage reservoir, a respirator test setup, and sample collection and analysis system. Sampling bias determined when in facepiece samples were collected during inhalation ranged from greater than -99 percent to more than +98 percent with a mean sampling bias of -17 percent. The range of fit factors for measured in facepiece concentrations was 44 to 4728. The actual fit factor was 87. The authors conclude that faceseal leakage is not mixing uniformly within the facepiece cavity, resulting in significant errors in estimates of within respirator sample concentrations. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0002-8894
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:106-114
-
Volume:47
-
Issue:2
-
NIOSHTIC Number:nn:00175092
-
Citation:Am Ind Hyg Assoc J 1986 Feb; 47(2):106-114
-
CAS Registry Number:
-
Federal Fiscal Year:1986
-
Peer Reviewed:True
-
Source Full Name:American Industrial Hygiene Association Journal
-
Collection(s):
-
Main Document Checksum:urn:sha-512:644d57fb9cefbad2e5f5b8d6714bee83f0707704d5d31da8f9f5dff5d154f3afadba09b51c90bdeb2744ad9dc7924d98c2e007b7bb9be32b32eefc97aaf1f561
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like