Particle size-dependent leakage and losses of aerosols in respirators.
-
1987/10/01
-
Details
-
Personal Author:
-
Description:The mechanisms of particle size dependent aerosol leakage into respirators were investigated. Leakage into a negative pressure half mask respirator equipped with air purifying cartridges worn by a human subject was measured utilizing three aerosols, a fine aerosol consisting of a mixture of smoke from burning incense and nebulized corn-oil, limestone dust, and corn-oil. The aerosols contained particles with diameters of 0.07 to 4.4 microns. Leakage was evaluated by measuring particle concentrations inside and outside the mask by an electrostatic aerosol classifier, condensation nucleus counter, active scattering aerosol spectrometer, or aerodynamic particle sizer. Comparison leakage tests utilizing 0.57, 1.07, or 1.68 millimeter (mm) diameter holes located at different places in the respirator, slits 4 or 10mm long, and sample probes placed in different locations inside the respirator were conducted. Total and particle size dependent leakage were strongly affected by where the holes and sampling probes were located. Total leakage was greater when a hole was placed in the chin area than when it was located near the nose. The further the sampling probe was from the leak site and closer it was to the clean air supply, the smaller the amount of leakage that was measured. Leakage of aerosol particles having diameters of 0.2 to 1.0 microns was not significantly affected by hole size. Total leakage decreased as hole size decreased; however, a greater percentage of large particles entered the hole as the hole size was decreased. Leakage was greater through circular holes than through slits. Leakage was not affected by slit length. The authors conclude that the location of the leak and sampling probe can exert a significant effect on the amount of leakage measured in a respirator. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0002-8894
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Volume:48
-
Issue:10
-
NIOSHTIC Number:nn:00173882
-
Citation:Am Ind Hyg Assoc J 1987 Oct; 48(10):848-854
-
Contact Point Address:Environmental Health University of Cincinnati Dept of Environmental Health Cincinnati, Ohio 45267
-
Federal Fiscal Year:1988
-
Performing Organization:University of Cincinnati, Cincinnati, Ohio
-
Peer Reviewed:True
-
Start Date:19810701
-
Source Full Name:American Industrial Hygiene Association Journal
-
End Date:19920831
-
Collection(s):
-
Main Document Checksum:urn:sha-512:3c7cbecaa32f0171d7f88ae09dbe2637294e2c45618f60f449b8a4a13d65b34d2ec974e9873000d21349a45bc9ac6465475dbc5d16939b9e3c5ce00335362b5d
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like