CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
i
Health Hazard Evaluation Report: HETA-85-345-1665: County of Alameda; Oakland, California
-
1986/02/01
Details:
-
Personal Author:
-
Corporate Authors:
-
Description:Air quality in the Data Processing Department of the County of Alameda, Oakland, California was investigated on May 16, and June 14, 1985. The evaluation was requested by a representative of the Personnel Department, Occupational Health Services, County of Alameda, Oakland, California to investigate indoor air quality problems. Workers had complained about room air temperature, and symptoms such as stuffy head, headaches, burning eyes and raspy throat. There also was concern that the ventilation intake duct at street level might be capturing vehicle exhaust fumes. Approximately 70 to 80 programmers and clerical staff work in the Data Processing Department, which is located in a large windowless room in the basement. An initial environmental survey was conducted in May
in June, carbon-monoxide (630080) (CO), carbon-dioxide (124389) (CO2) and formaldehyde (50000) concentrations in the air were measured using chemical detector tubes. CO air concentrations ranged from 2 to 3 parts per million (ppm), while CO2 air concentrations ranged from 500 to 700ppm. No formaldehyde was detected. Of 17 workers interviewed, 6 with asthma or allergies described eye, nose or throat symptoms. Air temperature and relative humidity were within ASHRAE standards for indoor air (72 to 79 degrees-F, relative humidity 20 to 60 percent). The author concluded that there were no overexposures to CO, CO2, or formaldehyde, and that workers' complaints may be related to an improperly balanced ventilation system and cigarette smoke. Recommendations are given for improving air quality within this workplace.
-
Subjects:
-
Keywords:
-
Series:
-
Subseries:
-
DOI:
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:12 pdf pages
-
NIOSHTIC Number:nn:00163100
-
NTIS Accession Number:PB86-221629
-
Citation:Cincinnati, OH: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control, National Institute for Occupational Safety and Health, HETA 85-345-1665, 1986 Feb;:1-10;
-
CAS Registry Number:
-
Federal Fiscal Year:1986
-
Peer Reviewed:False
-
NAICS and SIC Codes:
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: