Description:On October 6, 1993, a 27-year-old male drill rig operator was electrocuted when a radio antenna on top of his drill rig boom contacted a 7,200-volt overhead power line. The incident occurred when the victim and two helpers were preparing to drill a water well in the front yard of a private home. As the victim stood at the controls and raised the boom, the antenna contacted the powerline, energizing the drill rig and electrocuting the victim. NJDOH FACE investigators concluded that, in order to prevent similar incidents in the future, the following safety guidelines should be followed: 1. A minimum clearance of 10 feet must be maintained between equipment and energized power lines. 2. Employers should contact the utility company for assistance and advice when circumstances require operating less than 10 feet from power lines. 3. Drilling equipment should be posted with signs warning of contact with overhead power lines. 4. Employers should develop a clear system of communication between spotters and drill rig operators. 5. Antennas or other unnecessary extensions should not be placed on drill towers.
-
Subjects:
-
Keywords:
-
FACE - NIOSH and State:
-
Series:
-
Subseries:
-
DOI:
-
Publisher:
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:5 pdf pages
-
NIOSHTIC Number:20026564
-
NTIS Accession Number:PB2013-109346
-
Citation:Morgantown, WV: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, FACE 93NJ089, 1994 Apr; :1-5
-
Federal Fiscal Year:1994
-
Performing Organization:New Jersey Department of Health
-
Peer Reviewed:False
-
NAICS and SIC Codes:
-
Start Date:1991/09/30
-
End Date:2005/08/31
-
Resource Number:FACE-93NJ089
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: