Sign Company Owner and Helper Electrocuted When a Sign Post Contacts an Overhead Power Line
-
1998/08/21
Details:
-
Corporate Authors:
-
Description:On March 24, 1998, the 41-year-old owner of a sign company and his 60-year-old helper were electrocuted when the sign post they were raising struck a 7,200 volt overhead power line. The company was hired to raise a sign at a gas station that was being renovated. Setting their truck-mounted crane near the corner of the lot, the owner stood on the truck to operate the crane controls. His helper (who was not employed by the company) was on the ground to guide the signpost over a concrete pad. As the owner extended the crane boom, the pole struck a 7,200-volt overhead power line, electrocuting the helper. The owner saw his friend fall and jumped from the truck to help him. He was electrocuted when he contacted the energized truck while on the ground. The NJDHSS FACE program recommends following these safety guidelines to prevent similar incidents: 1. A minimum clearance of 10 feet must be maintained between equipment and power lines to prevent inadvertent contact. 2. Employers should conduct a job hazard analysis of all work activities with the participation of the workers. 3. Cranes should be posted with signs warning of contact with overhead power lines. 4. Employers should become familiar with available resources on safety standards and safe work practices.
-
Subjects:
-
Keywords:
-
FACE - NIOSH and State:
-
Series:
-
Subseries:
-
DOI:
-
Publisher:
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:8 pdf pages
-
NIOSHTIC Number:20026673
-
NTIS Accession Number:PB2013-100195
-
Citation:Morgantown, WV: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, FACE 98NJ025, 1998 Aug; :1-8
-
Federal Fiscal Year:1998
-
Performing Organization:New Jersey Department of Health
-
Peer Reviewed:False
-
NAICS and SIC Codes:
-
Start Date:1991/09/30
-
End Date:2005/08/31
-
Resource Number:FACE-98NJ025;FACE 98-NJ-025-01;
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: