Laborer Electrocuted When Antenna on Top of Steel Pole Building Contacts 14400-Volt Energized Line
-
2003/12/06
File Language:
English
Details
-
Corporate Authors:
-
Description:On December 5, 2002, a 48-year-old male laborer was electrocuted when a county road commission steel pole-building antenna contacted an energized 14,400-volt overhead power line while the building was being relocated via a state highway. An electric company lineman, a cable company employee, road commission employees and a police escort were on site. The building was positioned on three dollies, two steer dollies at the "rear" of the building and one dolly at the "front" of the building that hooked to the tow vehicle. The lineman dropped the neutral wire from the pole and left the 14,400-volt electrical lines energized. The lineman was present in an aerial bucket positioned on the road shoulder to observe building clearance while the building was being moved. Approximately 75 feet of the building had proceeded under the lines when two employees assigned to the "rear" steer dollies went under the building and began to ratchet each dolly chain to steer the rear of the building onto the road. (See Figure 1). Near the front of the building a "bolt of lightning" was observed as the building antenna contacted the line. The two employees at the "rear" steer dollies received electrical shocks and fell to the ground. Bystander CPR was initiated, and emergency response was called. One of the workers was taken to the hospital and survived, the other worker was pronounced dead at the scene. Recommendations: 1. Employers should verify that a minimum of 10 feet is maintained by employees when working near an energized electrical line, gear or equipment exposed to contact with an energized overhead power line. 2. Develop a building assessment standard operating procedure that includes roof protrusions regardless of building height as part of a company specific Accident Prevention Plan that is in compliance with MIOSHA requirements. 3. Stress and routinely review the hazards regarding overhead power lines so that all employees are cognizant of these energized sources. 4. Select personal protective equipment and other equipment insulating materials to provide operator protection from inadvertent contact with electricity. 5. Companies should not use skip boards to raise electrical or other overhead lines. 6. Additionally, MIFACE recommends that electric utility companies review their policy for communicating with individuals prior to work that will be performed within the vicinity of an energized overhead power line and the documentation procedures of this communication.
-
Content Notes:Publication Date provided by FACE program
not printed on the report.
-
Subjects:
-
Keywords:
-
FACE - NIOSH and State:
-
Series:
-
Subseries:
-
DOI:
-
Publisher:
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:10 pdf pages
-
NIOSHTIC Number:nn:20026818
-
NTIS Accession Number:PB2006-110736
-
Citation:Morgantown, WV: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, FACE 02MI208, 2003 Dec ; :1-10
-
Federal Fiscal Year:2004
-
Performing Organization:Michigan State University
-
Peer Reviewed:False
-
NAICS and SIC Codes:
-
Start Date:2002/09/01
-
End Date:2006/08/31
-
Collection(s):
-
Main Document Checksum:urn:sha-512:1016935330589f32eb4b84ebf87fc52b87a982a51c51d221dbe6d8bf386c344d77967e3b698b2902ee8a736ba6a8c5a458617f8a61b9686d95d7d7e3524b3ce5
-
Download URL:
-
File Type:
File Language:
English
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like