i
Firefighter is Electrocuted After Contacting Overhead Power Line
-
2015/08/12
Details:
-
Corporate Authors:
-
Description:On August 21, 2014, four firefighters arrived at a local university to assist in a national disease fundraising event. After debating where to set up their tower truck, the firefighters parked the tower truck close to a hydrant and two drains to protect landscape and provide drainage. Overhead power lines were present at all locations discussed. Firefighters 1 and 2 were in the bucket of the tower truck, a third firefighter was on the turntable of the truck opening the valves to access the water, while firefighter 4 was by the back of the truck watching the university film crew tape the introduction. Fundraising participants stood in front of the tower truck and firefighters opened the hose and sprayed them as they sang their school's song. Once the song finished the crowd thanked the firemen and dispersed. As the firefighters disassembled, one witness noticed that while attempting to dock, the bucket moved upward towards power lines instead of lowering. Firefighter 1, who was in control of the bucket, struck the powered electrical line sending a charge throughout the tower truck. Firefighter 1 then slumped down and witnesses heard him moaning. The victim then stood and struck the power line again with the left side of his head. Firefighter 2 who was also in the bucket with Firefighter 1 yelled for help. At 11:44 am, emergency medical services were dispatched to the scene and arrived at 11:48 am. Paramedics treated firefighters 3 and 4 for non-life threatening injuries, and transported them to a local hospital. Firefighter 2 was transported first to a regional hospital then flown to a trauma center with electrical burns. Firefighter 1 was directly airlifted to a trauma center and succumbed to his injuries one month later from electrical burn complications. To prevent future occurrences of similar incidents, the following recommendations have been made: Recommendation No. 1: Whenever possible, avoid operating tower trucks where overhead power lines are present. Recommendation No. 2: Employers should ensure that firefighters wear protective head gear, footwear, and gloves, especially in a bucket where power lines are present. Recommendation No. 3: Employers should designate a spotter on the ground to observe each time the bucket is raised and lowered. Recommendation No.4: Employers should ensure bucket equipment is inspected as recommended by the manufacturer. Recommendation No 5: A communication intercom system from base to bucket should be established when the aerial truck is in use.
-
Subjects:
-
Keywords:
-
FACE - NIOSH and State:
-
Series:
-
Subseries:
-
DOI:
-
Publisher:
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:1-10
-
NIOSHTIC Number:20047582
-
NTIS Accession Number:PB2016-102592
-
Citation:Morgantown, WV: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, FACE 14KY049, 2015 Feb; :1-10
-
Federal Fiscal Year:2015
-
Performing Organization:University of Kentucky
-
Peer Reviewed:False
-
NAICS and SIC Codes:
-
Start Date:2005/07/01
-
End Date:2026/06/30
-
Resource Number:FACE-14KY049
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: