Nine Career Fire Fighters Die in Rapid Fire Progression at Commercial Furniture Showroom – South Carolina

Public Domain
File Language:
English


Details

  • Personal Author:
  • Corporate Authors:
  • Description:
    Death in the Line of Duty…a Summary of a NIOSH Fire Fighter Fatality Investigation

    On June 18, 2007, nine career fire fighters (all males, ages 27 - 56) died when they became disoriented and ran out of air in rapidly deteriorating conditions inside a burning commercial furniture showroom and warehouse facility. The first arriving engine company found a rapidly growing fire at the enclosed loading dock connecting the showroom to the warehouse. The Assistant Chief entered the main showroom entrance at the front of the structure but did not find any signs of fire or smoke in the main showroom. He observed fire inside the structure when a door connecting the rear of the right showroom addition to the loading dock was opened. Within minutes, the fire rapidly spread into and above the main showroom, the right showroom addition, and the warehouse. The burning furniture quickly generated a huge amount of toxic and highly flammable gases along with soot and products of incomplete combustion that added to the fuel load. The fire overwhelmed the interior attack and the interior crews became disoriented when thick black smoke filled the showrooms from ceiling to floor. The interior fire fighters realized they were in trouble and began to radio for assistance as the heat intensified. One fire fighter activated the emergency button on his radio. The front showroom windows were knocked out and fire fighters, including a crew from a mutual-aid department, were sent inside to search for the missing fire fighters. Soon after, the flammable mixture of combustion by-products ignited, and fire raced through the main showroom. Interior fire fighters were caught in the rapid fire progression and nine fire fighters from the first-responding fire department died. At least nine other fire fighters, including two mutual-aid fire fighters, barely escaped serious injury. NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should: 1. develop, implement and enforce written standard operating procedures (SOPs) for an occupational safety and health program in accordance with NFPA 1500

    2. develop, implement, and enforce a written Incident Management System to be followed at all emergency incident operations

    3. develop, implement, and enforce written SOPs that identify incident management training standards and requirements for members expected to serve in command roles

    4. ensure that the Incident Commander is clearly identified as the only individual with overall authority and responsibility for management of all activities at an incident

    5. ensure that the Incident Commander conducts an initial size-up and risk assessment of the incident scene before beginning interior fire fighting operations

    6. train fire fighters to communicate interior conditions to the Incident Commander as soon as possible and to provide regular updates

    7. ensure that the Incident Commander establishes a stationary command post, maintains the role of director of fireground operations, and does not become involved in fire-fighting efforts

    8. ensure the early implementation of division / group command into the Incident Command System

    9. ensure that the Incident Commander continuously evaluates the risk versus gain when determining whether the fire suppression operation will be offensive or defensive

    10. ensure that the Incident Commander maintains close accountability for all personnel operating on the fireground

    11. ensure that a separate Incident Safety Officer, independent from the Incident Commander, is appointed at each structure fire

    12. ensure that crew integrity is maintained during fire suppression operations

    13. ensure that a rapid intervention crew (RIC) / rapid intervention team (RIT) is established and available to immediately respond to emergency rescue incidents

    14. ensure that adequate numbers of staff are available to immediately respond to emergency incidents

    15. ensure that ventilation to release heat and smoke is closely coordinated with interior fire suppression operations

    16. conduct pre-incident planning inspections of buildings within their jurisdictions to facilitate development of safe fireground strategies and tactics

    17. consider establishing and enforcing standardized resource deployment approaches and utilize dispatch entities to move resources to fill service gaps

    18. develop and coordinate pre-incident planning protocols with mutual aid departments

    19. ensure that any offensive attack is conducted using adequate fire streams based on characteristics of the structure and fuel load present

    20. ensure that an adequate water supply is established and maintained

    21. consider using exit locators such as high intensity floodlights or flashing strobe lights to guide lost or disoriented fire fighters to the exit

    22. ensure that Mayday transmissions are received and prioritized by the Incident Commander

    23. train fire fighters on actions to take if they become trapped or disoriented inside a burning structure

    24. ensure that all fire fighters and line officers receive fundamental and annual refresher training according to NFPA 1001 and NFPA 1021

    25. implement joint training on response protocols with mutual aid departments

    26. ensure apparatus operators are properly trained and familiar with their apparatus

    27. protect stretched hose lines from vehicular traffic and work with law enforcement or other appropriate agencies to provide traffic control

    28. ensure that fire fighters wear a full array of turnout clothing and personal protective equipment appropriate for the assigned task while participating in fire suppression and overhaul activities

    29. ensure that fire fighters are trained in air management techniques to ensure they receive the maximum benefit from their self-contained breathing apparatus (SCBA)

    30. develop, implement and enforce written SOPS to ensure that SCBA cylinders are fully charged and ready for use

    31. use thermal imaging cameras (TICs) during the initial size-up and search phases of a fire

    32. develop, implement and enforce written SOPs and provide fire fighters with training on the hazards of truss construction

    33. establish a system to facilitate the reporting of unsafe conditions or code violations to the appropriate authorities

    34. ensure that fire fighters and emergency responders are provided with effective incident rehabilitation

    35. provide fire fighters with station / work uniforms (e.g., pants and shirts) that are compliant with NFPA 1975 and ensure the use and proper care of these garments. Additionally, federal and state occupational safety and health administrations should consider developing additional regulations to improve the safety of fire fighters, including adopting National Fire Protection Association (NFPA) consensus standards. Additionally, manufacturers, equipment designers, and researchers should: 1. continue to develop and refine durable, easy-to-use radio systems to enhance verbal and radio communication in conjunction with properly worn SCBA

    2. conduct research into refining existing and developing new technology to track the movement of fire fighters inside structures. Additionally, code setting organizations and municipalities should: 1. require the use of sprinkler systems in commercial structures, especially ones having high fuel loads and other unique life-safety hazards, and establish retroactive requirements for the installation of fire sprinkler systems when additions to commercial buildings increase the fire and life safety hazards

    2. require the use of automatic ventilation systems in large commercial structures, especially ones having high fuel loads and other unique life-safety hazards. Additionally, municipalities and local authorities having jurisdiction should: 1. coordinate the collection of building information and the sharing of information between building authorities and fire departments

    2. consider establishing one central dispatch center to coordinate and communicate activities involving units from multiple jurisdictions

    3. ensure that fire departments responding to mutual aid incidents are equipped with mobile and portable communications equipment that are capable of handling the volume of radio traffic and allow communications among all responding companies within their jurisdiction.

  • Subjects:
  • Keywords:
  • FACE - Firefighter:
  • Series:
  • Subseries:
  • DOI:
  • Publisher:
  • Document Type:
  • Genre:
  • Place as Subject:
  • CIO:
  • Division:
  • Topic:
  • Location:
  • Pages in Document:
    1-74
  • Contributor:
    Stull, Jeffrey O. ; Brunacini, Alan ; Salka, John J., Jr. ; Routley, Gordon ; Roche, Kevin ; Bryner, Nelson ; Farmer, Ken ; Fuss, Paul ; Forney, Glenn ; Baughman, Lee
  • NIOSHTIC Number:
    nn:20035012
  • NTIS Accession Number:
    PB2018-100589
  • Citation:
    Morgantown, WV: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, FACE F2007-18, 2009 Feb ; :1-74
  • Federal Fiscal Year:
    2009
  • NORA Priority Area:
  • Peer Reviewed:
    False
  • NAICS and SIC Codes:
  • Start Date:
    2007/06/18
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:7160fd1488523a6e077331d957a254f7f766a1b739b0d7982bd44598700d67d4942429931623de179ac94322daddef304fd9c2cf28e1dcb0ceadd81a90e8f587
  • Download URL:
  • File Type:
    Filetype[PDF - 4.28 MB ]
File Language:
English
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.